4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN Bosch Rexroth Indramat

MPN: R912007797

No Tariffs On US Orders
  • Rated 4.5 (67 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 56 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN belongs to the EFC Frequency Converters series and is designed for use with a three-phase mains voltage of 200 to 240 V AC. This frequency converter has a motor power rating of 3.0 kW under heavy duty conditions and features standard vector control SVC with a flex-control section and standard I/O. It includes Modbus communication, an IP20 protection class, and a Safe Torque Off safety function.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN is a frequency converter produced by Bosch Rexroth Indramat within the EFC Frequency Converters series. As a member of the EFC 5610 model line, it is installed in industrial automation to adjust asynchronous motor speed and torque for process equipment, conveyors, and pump drives. The unit belongs to the frequency converter product group, so it accepts fixed-frequency mains power and delivers a variable output waveform that matches real-time load demands.

For networking, the drive uses the Modbus protocol, allowing basic parameter access from PLCs or HMIs. Motion is regulated with standard vector control (SVC), which maintains flux and torque even at low speed. The power stage is sized for 200 V AC (200 to 240 V ±10%) supplies and delivers up to 3.0 kW in heavy-duty service. Connection to a three-phase feeder reduces line current per conductor and supports regenerative braking when configured. Within product line 02, the device retains a standard control configuration and the Flex-Control section with standard I/O, so digital inputs, relay outputs, and analog channels are available for direct field wiring. Frame size E keeps the mechanical dimensions consistent across the 5610 range.

An integrated EMC filter rated for industrial area, class C3 attenuates conducted emissions, enabling compliance on unshielded cable runs. The housing meets the IP20 protection class, so live parts are finger-safe when the converter is mounted in a sealed panel. For functional safety, the hardware implements Safe Torque Off (STO); when the STO circuit is energized, the power stage is disabled without relying on software commands. A standard LCD display with potentiometer on the front plate provides local parameter editing and real-time speed trimming, supplementing the fieldbus interface.

Communication Protocol
Modbus
Control Configuration
Standard
Control Section Design
Flex-Control with Standard I/O
Control Type
Standard Vector control SVC
Display Type
Standard LCD display with potentiometer
EMC Filter Type
Industrial area, class C3
Frame Size
E
Mains Voltage
200 V (AC 200...240 V +/- 10%)
Model Series
EFC 5610
Motor Power (Heavy Duty)
3.0 kW
Phase Configuration
Three phases
Product Group
Frequency Converter
Product Line
02
Protection Class
IP 20
Safety Function
Safe Torque Off (STO)
Variant
None
  • EFC5610 3K00 3P2 MDA 7P NNNNN L1NN
  • EFC56103K003P2MDA7PNNNNNL1NN
  • efc5610-3k00-3p2-mda-7p-nnnnn-l1nn

Frequently Asked Questions about EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN:

Q: What communication protocol is available on the EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN frequency converter?

A: The EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN supports the Modbus communication protocol for integration with industrial control systems.

Q: What safety function does the EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN offer?

A: This model provides safe operation with an integrated Safe Torque Off (STO) safety function.

Q: What is the maximum motor power supported by the EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN?

A: The EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN is capable of delivering 3.0 kW of motor power under heavy duty conditions.

Q: What mains voltage range does the EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN support?

A: This frequency converter is designed for three-phase mains voltage in the range of 200...240 V AC, with a ±10% tolerance.

Q: What display and control options are available on the EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN frequency converter?

A: The display on this model is a standard LCD with an integrated potentiometer for convenient parameter adjustment.


Internal Product Review

  • ‘‘The EFC5610-3K00-3P2-MDA-7P-NNNNN-L1NN is a frequency converter built for three-phase operation. Standard Vector control SVC and Modbus communication give this unit strong drive response and straightforward network integration. Safe Torque Off adds valuable machine safety support, making this converter a well-rounded choice for industrial motion control.’’