4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN Bosch Rexroth Indramat

MPN: R912007165

No Tariffs On US Orders
  • Rated 4.6 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 38 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN is part of the EFC Frequency Converters series and features a heavy duty motor power of 30.0 kW with a maximum output capacity of 40.0 kVA. It operates with three phases at 400 V and includes Modbus communication, Safe Torque Off safety function, and an IP20 protection class. This frequency converter uses Standard Vector control and has Flex-Control with Standard I/O, as well as a standard LCD display with potentiometer.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN frequency converter manufactured by Bosch Rexroth Indramat belongs to the EFC Frequency Converters series and the internal model series EFC 5610. Designed for variable-speed control of induction and synchronous motors, the unit modulates the AC supply to match commanded torque and speed in automated machinery and process lines. As a member of the Frequency Converter product group and product line 02, it provides vector-based control for control cabinets where space is limited and open-chassis IP20 protection is acceptable.

For power connectivity, the converter accepts a three-phase supply in the range of 400 V (AC 380…480 V -15% / +10%). Under a heavy-duty rating, it delivers 30.0 kW of motor power with a continuous output current of 60.8 A, which corresponds to an apparent output of 40.0 kVA. The housing is rated IP 20, so it is intended for dry, dust-controlled enclosures. The frame is classified as size H, allowing panel mounting without external heat sinks. Internal standard vector control SVC maintains motor flux even at low frequencies, while the Flex-Control section with standard I/O supplies local digital and analog terminals for start, speed reference, and fault signaling.

Bus communication is provided through Modbus, enabling parameter access from PLCs without proprietary adapters. For functional safety, the integrated Safe Torque Off (STO) circuit disconnects gate drives so the motor cannot unintentionally energize. Electromagnetic compliance in industrial networks is supported by the industrial area, class C3 filter on the line side of the device. The standard control configuration requires no additional option cards, and the LCD display with potentiometer supports local adjustment of frequency, acceleration time, and diagnostic codes. Because the product is part of line 02 of the family, its parameter structure remains consistent with earlier EFC 5610 units.

Communication Protocol
Modbus
Control Configuration
Standard
Control Section Design
Flex-Control with Standard I/O
Control Type
Standard Vector control SVC
Display Type
Standard LCD display with potentiometer
EMC Filter Type
Industrial area, class C3
Frame Size
H
Mains Voltage
400 V (AC 380...480 V -15% / +10%)
Model Series
EFC 5610
Motor Power (Heavy Duty)
30.0 kW
Output Capacity
40.0 kVA
Output Current (at 400V)
60.8 A
Phase Configuration
Three phases
Product Group
Frequency Converter
Product Line
02
Protection Class
IP 20
Safety Function
Safe Torque Off (STO)
  • EFC5610 30K0 3P4 MDA 7P DRNNN L1NN
  • EFC561030K03P4MDA7PDRNNNL1NN
  • efc5610-30k0-3p4-mda-7p-drnnn-l1nn

Frequently Asked Questions about EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN:

Q: What communication protocol does the EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN frequency converter use?

A: The EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN supports communication via Modbus protocol.

Q: What is the heavy-duty motor power rating of the EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN?

A: This frequency converter delivers a motor power of 30.0 kW for heavy-duty applications.

Q: What type of display is included with the EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN?

A: The EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN features a standard LCD display with a potentiometer for straightforward operation.

Q: What are the mains voltage requirements for the EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN?

A: The main supply voltage supported is 400 V, with an operational range from 380 V to 480 V AC and volatility of -15% to +10%.

Q: What safety function is provided on the EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN frequency converter?

A: This model is equipped with a Safe Torque Off (STO) safety function for secure operation.


Internal Product Review

  • ‘‘The EFC5610-30K0-3P4-MDA-7P-DRNNN-L1NN is an EFC 5610 frequency converter designed for three-phase 400 V mains service. Standard Vector control SVC and Flex-Control with Standard I/O give the unit responsive regulation and straightforward integration. Modbus communication and Safe Torque Off (STO) make this converter a strong choice for modern industrial drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo