4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN Bosch Rexroth Indramat

MPN: R912007539

No Tariffs On US Orders
  • Rated 4.4 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
3 Minutes 22 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN is a frequency converter from the EFC Frequency Converters series. It supports Modbus communication, has a motor power of 2.2 kW for heavy duty applications, and operates with three-phase mains voltage at 400 V. This model features standard vector control, an IP20 protection class, and a standard LCD display with potentiometer.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN frequency converter is built by Bosch Rexroth Indramat and belongs to the EFC Frequency Converters series. Within an automation cell, this unit sits between the mains supply and an induction motor, adjusting output frequency so that machine speed follows the required process profile. Its role is to provide energy-efficient acceleration, deceleration, and steady-state speed control for equipment connected to standard three-phase networks. This operating method helps stabilize motor behavior during changing load conditions and supports smooth speed transitions in routine process duty.

The drive is supplied from a mains bus at 400 V (AC 380...480 V -15% / +10%) and fits the medium power frame size D. Field integration is simplified by the built-in Modbus interface, which allows start, stop, and parameter commands from a PLC without separate gateways. Motor flux is managed through standard vector control (SVC), and this control method supports stable torque response across the speed range. Operators can change setpoints locally through a standard LCD display with a potentiometer, which gives direct access to routine operating adjustments at the drive. Conducted emissions are attenuated by an internal filter rated for industrial area, Class C3 environments. This arrangement suits installations that need both networked control and orderly panel integration.

Heavy-duty applications are covered by a continuous motor output of 2.2 kW, coordinated by the controller’s Flex-Control with Standard I/O section that offers configurable digital and analog terminals for field wiring. The housing has an IP 20 protection class, so it must be installed inside a panel and uses natural airflow for cooling. For personnel protection, the unit includes Safe Torque Off (STO), which removes gate signals to the power stage without relying on mechanical relays. The available control and wiring functions support enclosed installations used for conveyor sections, mixers, and pump assemblies where compact drive layout and straightforward signal routing are required.

Communication Protocol
Modbus
Control Configuration
Standard
Control Section Design
Flex-Control with Standard I/O
Control Type
Standard Vector control SVC
Display Type
Standard LCD display with potentiometer
EMC Filter Type
Industrial area, class C3
Frame Size
D
Mains Voltage
400 V (AC 380...480 V -15% / +10%)
Model Series
EFC 5610
Motor Power (Heavy Duty)
2.2 kW
Phase Configuration
Three phases
Product Group
Frequency Converter
Product Line
02
Protection Class
IP 20
Safety Function
Safe Torque Off (STO)
  • EFC5610 2K20 3P4 MDA 7P FCPNN L1NN
  • EFC56102K203P4MDA7PFCPNNL1NN
  • efc5610-2k20-3p4-mda-7p-fcpnn-l1nn

Frequently Asked Questions about EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN:

Q: What communication protocol does the EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN frequency converter use?

A: The EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN supports the Modbus communication protocol for integration with automation systems.

Q: What type of display and controls are provided on the EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN?

A: This model is equipped with a Standard LCD display and an integrated potentiometer for simple local operation.

Q: What is the input voltage range for the EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN?

A: The frequency converter operates at a mains voltage range of 380 to 480 V AC, with a tolerance of -15% to +10%.

Q: What level of protection does the EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN offer?

A: The EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN features an IP 20 protection class, indicating limited protection against dust and no protection against water.

Q: What safety function is included with the EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN?

A: Safe Torque Off (STO) is integrated as a safety feature on this model, enabling secure motor deactivation without shutting off the main power supply.


Internal Product Review

  • ‘‘The EFC5610-2K20-3P4-MDA-7P-FCPNN-L1NN is a frequency converter designed for 400 V three-phase drive applications. Standard Vector control SVC and Modbus communication support precise speed regulation and straightforward system integration. IP 20 protection and Safe Torque Off make this unit a strong choice for controlled industrial environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo