EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN Bosch Rexroth Indramat
MPN: R912007433
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
0 Seconds
The Bosch Rexroth Indramat EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN is part of the EFC Frequency Converters series and delivers a motor power of 15.0 kW in heavy duty operation. This three-phase frequency converter uses Standard Vector control SVC, features an IP20 protection class, and communicates via Modbus protocol. It comes with a Flex-Control section design, standard LCD display with potentiometer, and includes Safe Torque Off safety function.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN is an AC frequency converter supplied by Bosch Rexroth Indramat within the EFC Frequency Converters series. The unit belongs to the EFC 5610 model range and is part of product line 02. By converting fixed-frequency mains power into a variable output frequency and voltage, it supports closed-loop speed and torque regulation of induction motors used in conveyors, pumps, and other automated plant equipment. It is intended for variable-speed motor control rather than direct across-the-line operation.
For integration with plant power systems, the converter is specified for a mains input of 400 V (AC 380…480 V -15% / +10%) on three-phase power. This input range allows use on common industrial mains across a broad voltage window. In heavy-duty mode, it can drive motors up to 15.0 kW. Motion is regulated with standard vector control (SVC), which manages flux and torque independently for stable acceleration and smoother low-speed operation. Communication with higher-level controllers is available through Modbus, allowing parameter changes, status exchange, and diagnostics over a serial link. The control hardware uses the Flex-Control section with standard I/O, and the enclosure uses frame size F for cabinet installation.
For operator interaction, a standard LCD display with a potentiometer provides direct setpoint entry and alarm readout. The integrated EMC filter is rated for industrial area, Class C3, which helps limit conducted emissions on longer motor cables. Functional safety is provided by the built-in Safe Torque Off (STO) circuit, which removes gate signals from the power stage without external contactors. The housing has an IP20 rating, so the converter is intended for installation inside a closed switchgear panel where the cabinet supplies added physical protection.
Frequently Asked Questions about EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN:
Q: What is the motor power rating for the EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN frequency converter?
A: This model provides a heavy duty motor power rating of 15.0 kW.
Q: What mains voltage range is supported by the EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN?
A: The EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN operates with three-phase mains voltage between 380 and 480 V AC, with a tolerance of -15% to +10%.
Q: What type of display does the EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN use?
A: This frequency converter features a standard LCD display with a potentiometer for user interface.
Q: Which communication protocol is available on the EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN?
A: The EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN supports the Modbus communication protocol for integration and control.
Q: What safety function is provided with the EFC5610-15K0-3P4-MDA-7P-SVPNN-L1NN?
A: This model includes the Safe Torque Off (STO) safety function for enhanced operational safety.