The Bosch Rexroth Indramat EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN is a frequency converter from the EFC Frequency Converters series. It features a motor power of 0.75 kW for heavy duty use and supports a single phase mains voltage of 200 to 240 V AC. The converter offers Modbus communication, standard vector control, and Safe Torque Off (STO) safety function, with an IP20 protection class.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN is a frequency converter produced by Bosch Rexroth Indramat as part of the EFC Frequency Converters series. Designed for panel mounting inside control cabinets, it converts fixed mains voltage into a variable output for small AC motors used in conveyors, fans, and other general-purpose machinery. By modulating both frequency and amplitude, the unit supports precise speed adjustment, improved energy use, and steadier process control. Its compact footprint also suits machine layouts where cabinet space is limited and a full-size drive would be unnecessary. It is suitable for applications that need repeatable motor response across changing loads, such as simple transport systems or small process stations.

This model accepts an input of 200–240 V AC with a tolerance of ±10%. From that supply, it can deliver up to 0.75 kW of heavy-duty motor power for small machines that still need controlled acceleration and stable running speed. It uses standard vector control (SVC), so torque remains steady at low speed without external feedback. An EMC stage rated for class C3 limits conducted emissions, and Safe Torque Off (STO) removes drive energy during an emergency stop. The standard control configuration includes Flex-Control I/O with eight digital inputs, two digital outputs, and analog terminals for routine machine signals. This arrangement supports common start-stop commands, speed references, and status signaling without requiring additional control hardware at the outset.

Parameter access is handled through a standard LCD display with potentiometer, so local setup can be done without an external keypad. For higher-level supervision, the converter communicates via Modbus over RS-485, allowing register-based control from many PLCs and similar controllers. The power stage is arranged for single-phase operation, and the housing has IP20 protection, so the unit must be mounted inside a closed panel. That enclosure placement helps protect the drive from direct contact and airborne contamination in open machine areas. Using the front display also allows quick parameter review when cabinet access is available.

Communication Protocol
Modbus
Control Configuration
Standard
Control Section Design
Flex-Control with Standard I/O
Control Type
Standard Vector control SVC
Display Type
Standard LCD display with potentiometer
EMC Filter Type
Industrial area, class C3
Frame Size
B (1P) / C (3P)
Mains Voltage
200 V (AC 200...240 V +/- 10%)
Model Series
EFC 5610
Motor Power (Heavy Duty)
0.75 kW
Phase Configuration
Single phase
Product Group
Frequency Converter
Product Line
02
Protection Class
IP 20
Safety Function
Safe Torque Off (STO)
Variant
None
  • EFC56100K751P2MDA7PNNNNNL1NN
  • efc5610-0k75-1p2-mda-7p-nnnnn-l1nn
  • EFC5610 0K75 1P2 MDA 7P NNNNN L1NN

Frequently Asked Questions about EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN:

Q: What communication protocol is used by the EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN?

A: This model supports the Modbus communication protocol for simple integration with industrial networks.

Q: What phase configuration does the EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN support?

A: A single-phase power supply is required for this frequency converter.

Q: What is the heavy duty motor power rating of the EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN?

A: The rated motor power for heavy duty operation is 0.75 kW.

Q: What safety function is included with the EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN converter?

A: This device is equipped with an integrated Safe Torque Off (STO) safety function.

Q: What type of display does the EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN provide?

A: The frequency converter features a standard LCD display with a potentiometer for easy operation and monitoring.


Internal Product Review

  • ‘‘The EFC5610-0K75-1P2-MDA-7P-NNNNN-L1NN is an EFC frequency converter with standard vector control for efficient motor management. Flex-Control with Standard I/O and Modbus communication make integration and commissioning straightforward in typical industrial panels. Safe Torque Off and IP20 protection add practical safety value, making this unit a strong choice for compact drive applications.’’