The Bosch Rexroth Indramat EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN is part of the EFC Frequency Converters series and supports a mains voltage of 400 V with a three-phase configuration. This converter features standard vector control SVC, a Modbus communication protocol, and a standard LCD display with potentiometer. It has 0.4 kW motor power in heavy duty mode and is rated for IP20 protection class.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN frequency converter is built by Bosch Rexroth Indramat and belongs to the EFC Frequency Converters series within the EFC 5610 model range. It is installed between the plant mains and an AC motor to vary speed and torque on demand. By adjusting output frequency and voltage, the unit supports energy-efficient operation of conveyors, pumps, and fans across automated production lines. Its compact design also suits control cabinets where space is limited and stable motor regulation is required during everyday operation.
The device accepts a mains supply of 400 V on three-phase power, a range that matches common 380 to 480 V plant grids and avoids the need for transformers. Under the heavy-duty rating, it delivers 0.4 kW of mechanical output for small pumps, light conveyors, and indexing applications that require continuous torque. Regulation is handled by a standard vector control algorithm in the standard control configuration, executed inside the Flex-Control section with standard I/O. For supervisory exchange, it uses Modbus, enabling parameter access and status polling through a simple serial link. An internal Industrial area, class C3 EMC filter attenuates conducted noise and helps reduce interference with nearby electrical devices.
The casing corresponds to frame size B, permitting side-by-side mounting in compact control panels. A front-mounted Standard LCD display with potentiometer provides plain-text setup access and allows local speed adjustment when needed. The integrated Safe Torque Off (STO) input removes gate power to the inverter stage for a controlled stop function within the drive system. The enclosure has a protection level of IP 20, so airflow openings remain accessible while live parts are finger-safe inside a clean cabinet. This layout supports straightforward panel installation and keeps routine operation easy to manage.
Frequently Asked Questions about EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN:
Q: What communication protocol does the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN use?
A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN supports Modbus as its communication protocol for integration with control systems.
Q: What safety function is provided on the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?
A: This frequency converter is equipped with a Safe Torque Off (STO) safety function for added operational safety.
Q: What is the motor power rating for heavy duty use on the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?
A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN has a motor power rating of 0.4 kW for heavy duty applications.
Q: What mains voltage range does the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN support?
A: This model is rated for a three-phase mains voltage of 400 V, supporting input voltages from 380 V to 480 V with -15% to +10% variation.
Q: What type of EMC filter is included with the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?
A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN features an EMC filter designed for industrial environments, classified as class C3.