4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN Bosch Rexroth Indramat

MPN: R912007558

No Tariffs On US Orders
  • Rated 4.6 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
6 Minutes 23 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN is part of the EFC Frequency Converters series and supports a mains voltage of 400 V with a three-phase configuration. This converter features standard vector control SVC, a Modbus communication protocol, and a standard LCD display with potentiometer. It has 0.4 kW motor power in heavy duty mode and is rated for IP20 protection class.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN frequency converter is built by Bosch Rexroth Indramat and belongs to the EFC Frequency Converters series within the EFC 5610 model range. It is installed between the plant mains and an AC motor to vary speed and torque on demand. By adjusting output frequency and voltage, the unit supports energy-efficient operation of conveyors, pumps, and fans across automated production lines. Its compact design also suits control cabinets where space is limited and stable motor regulation is required during everyday operation.

The device accepts a mains supply of 400 V on three-phase power, a range that matches common 380 to 480 V plant grids and avoids the need for transformers. Under the heavy-duty rating, it delivers 0.4 kW of mechanical output for small pumps, light conveyors, and indexing applications that require continuous torque. Regulation is handled by a standard vector control algorithm in the standard control configuration, executed inside the Flex-Control section with standard I/O. For supervisory exchange, it uses Modbus, enabling parameter access and status polling through a simple serial link. An internal Industrial area, class C3 EMC filter attenuates conducted noise and helps reduce interference with nearby electrical devices.

The casing corresponds to frame size B, permitting side-by-side mounting in compact control panels. A front-mounted Standard LCD display with potentiometer provides plain-text setup access and allows local speed adjustment when needed. The integrated Safe Torque Off (STO) input removes gate power to the inverter stage for a controlled stop function within the drive system. The enclosure has a protection level of IP 20, so airflow openings remain accessible while live parts are finger-safe inside a clean cabinet. This layout supports straightforward panel installation and keeps routine operation easy to manage.

Communication Protocol
Modbus
Control Configuration
Standard
Control Section Design
Flex-Control with Standard I/O
Control Type
Standard Vector control SVC
Display Type
Standard LCD display with potentiometer
EMC Filter Type
Industrial area, class C3
Frame Size
B
Mains Voltage
400 V (AC 380...480 V -15% / +10%)
Model Series
EFC 5610
Motor Power (Heavy Duty)
0.4 kW
Phase Configuration
Three phases
Product Group
Frequency Converter
Product Line
02
Protection Class
IP 20
Safety Function
Safe Torque Off (STO)
  • EFC5610 0K40 3P4 MDA 7P DRNNN L1NN
  • EFC56100K403P4MDA7PDRNNNL1NN
  • efc5610-0k40-3p4-mda-7p-drnnn-l1nn

Frequently Asked Questions about EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN:

Q: What communication protocol does the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN use?

A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN supports Modbus as its communication protocol for integration with control systems.

Q: What safety function is provided on the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?

A: This frequency converter is equipped with a Safe Torque Off (STO) safety function for added operational safety.

Q: What is the motor power rating for heavy duty use on the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?

A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN has a motor power rating of 0.4 kW for heavy duty applications.

Q: What mains voltage range does the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN support?

A: This model is rated for a three-phase mains voltage of 400 V, supporting input voltages from 380 V to 480 V with -15% to +10% variation.

Q: What type of EMC filter is included with the EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN?

A: The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN features an EMC filter designed for industrial environments, classified as class C3.


Internal Product Review

  • ‘‘The EFC5610-0K40-3P4-MDA-7P-DRNNN-L1NN is a Bosch Rexroth Indramat frequency converter suited to light-duty automation service. Standard Vector control SVC and Modbus communication provide precise speed regulation and straightforward integration with plant controls. IP20 protection and Safe Torque Off add practical cabinet-ready safety for dependable converter performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo