Bosch Rexroth Indramat DKC06.3-004-3-MGP-01VRS Drive Controller features a maximum allowed installation altitude of 2000 m and operates with a current rating of 4 A. The DKC06.3-004-3-MGP-01VRS offers RS232/485 interface, Analog interface, and a DKC06.3-LK-DVN01 optional card for DeviceNet interface.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The DKC06.3-004-3-MGP-01VRS by Bosch Rexroth is a drive controller and belongs to the DKC Controllers series. Bosch Rexroth Indramat is a well-known manufacturing company, which is specialized in producing highly advanced drive controllers and AC/DC motors to run complex industrial systems. This drive features power section cooling with an internal blower. The blower is fitted inside the unit and uses forced air to cool the internal driving parts of the controller during operation. Its efficient cooling makes it an ideal choice for heavy-duty operation, where temperature control is paramount.

The internal blower of the drive maintains its temperature within the ambient temperature range. It overcomes the chances of overheating and freezing because the temperature of the drive controller lower than the surrounding temperature could cause moisture condensation. The volumetric capacity of the internal blower is approximately 150 m^3/h. The rotary field of the controller can rotate both in the clockwise or anti-clockwise direction. The drive can work in an environment that has a maximum humidity level of 25 g/m^3. The drive works with a low input current of about 4 A and a control voltage of 19.2 ... 28.8 VDC. The halve sine of the drive is equal to 15 g / 11 ms. The DKC06.3-004-3-MGP-01VRS offers RS232/485 interface, Analog interface, and a DKC06.3-LK-DVN01 optional card for DeviceNet interface. The Analog interface allows basic control through varying voltage or current, and the RS232/485 interfaces enable serial communication for diagnostics and settings. The DeviceNet interface is employed for networked industrial devices.

For maximum output, It is recommended to use this drive in ambient conditions, which include nominal temperature and 2.2 g acceleration with a maximum elevation of 2000 m. The tolerance of the drive is high (~ 3 dB), which ensures that it can be operated in any industrial condition and heavy-duty equipment. This drive can withstand the spectral acceleration amplitude density of 0.01 g^2/Hz and can work with the overvoltage of 45 V for 1 ms.

Control voltage
DC (19.2 ... 28.8) V
Current rating
4:00 AM
Drive type
Drive controller
Frequency
20 ... 500 Hz
Halve sine in 3 axis
15 g / 11 ms
Max. allowed installation altitude
2000 m
max. allowed overvoltage
45 V for 1ms, non repetitive
max. charging current
6:00 AM
Max. permissible absolute humidity
25 g/m^3
Power section cooling
With internal blower
Rotary field
clockwise or counter-clockwise
Spectral acceleration density amplitude
0.01 g^2/Hz
Tolerance
~ 3 dB
Virtual value (r.m.s.) of the total acceleration
2.2 g
Volumetric capacity of the forced cooling
Approximately 150 m^3/h
  • DKC0630043MGP01VRS
  • DKC06 3 004 3 MGP 01VRS
  • dkc06.3-004-3-mgp-01vrs
  • DKC6.3-004-3-MGP-01VRS

Frequently Asked Questions about DKC06.3-004-3-MGP-01VRS:

Q: What is the control voltage range of the DKC06.3-004-3-MGP-01VRS drive controller?

A: The DKC06.3-004-3-MGP-01VRS operates with a control voltage range of 19.2V to 28.8V DC.

Q: What is the maximum allowed installation altitude for the DKC06.3-004-3-MGP-01VRS?

A: The DKC06.3-004-3-MGP-01VRS can be installed at altitudes up to 2000 meters.

Q: What is the maximum allowed overvoltage for the DKC06.3-004-3-MGP-01VRS?

A: The DKC06.3-004-3-MGP-01VRS can withstand a maximum overvoltage of 45V for 1 millisecond, non-repetitive.

Q: What type of cooling system does the DKC06.3-004-3-MGP-01VRS use?

A: The DKC06.3-004-3-MGP-01VRS is equipped with an internal blower for power section cooling.

Q: What is the volumetric capacity of the forced cooling in the DKC06.3-004-3-MGP-01VRS?

A: The forced cooling system of the DKC06.3-004-3-MGP-01VRS has a volumetric capacity of approximately 150 m^3/h.


Internal Product Review

  • ‘‘Designed to deliver stable performance even in challenging conditions, the DKC06.3-004-3-MGP-01VRS Drive Controller features a robust cooling system with an internal blower and excellent tolerance to acceleration and overvoltage. Its ability to operate effectively in high-altitude installations makes it highly versatile for various industrial applications.’’