4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW Bosch Rexroth Indramat

MPN: R911334857

No Tariffs On US Orders
  • Rated 4.3 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
6 Minutes 53 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW is part of the CSH Advanced Controllers series. It features SERCOS II master communication and supports Safe Torque Off safety functions. This controller offers one analog input, two analog outputs, and a serial RS232 interface with a maximum cable length of 15 meters.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW module is a motion and logic control card manufactured by Bosch Rexroth Indramat for the CSH Advanced Controllers series. It is designed to fit into Rexroth drive racks where it coordinates axis profiles, manages parameter sets, and routes field data to higher-level control networks used in industrial automation. By combining deterministic Ethernet links, analog channels, and an integrated safety input, the card supplies the real-time command layer needed in packaging machines, pick-and-place gantries, and similar multi-axis equipment.

The controller’s base circuitry dissipates 8.5 W, so thermal loading inside a closed cabinet remains modest. When power is first applied, a peak of 4 A flows for a 100 ms inrush window that must be considered in supply sizing. One analog input and two analog outputs allow direct connection of process transducers or reference generators without extra modules. For drive-to-drive coordination, the card exposes X24 and X25 cross-communication sockets and assumes the master role on that backplane. These ports communicate according to the IEEE 802.3 standard and accept traffic compatible with 100Base-TX signaling over industrial-rated twisted-pair cabling. The physical engineering interface is a shielded RJ-45, 8-pin connector, which simplifies connection with common patch cords.

Higher-level motion commands reach the board over the SERCOS II optical ring, while drive enable integrity is guarded by the integrated safety function known as Safe Torque Off. Parameter uploads and diagnostics can also be performed through the RS232 serial port, which supports cable runs up to 15 m and reaches a maximum rate of 115 kBaud. The female 9-pin D-Sub assigned to the STO circuit separates safety wiring from general control harnesses, and the controller’s cross-communication master capability lets it broadcast setpoints to subordinate axes without external switches or hubs.

Analog Inputs
1
Analog Outputs
2
Base Board Power
8.5 W
Base Inrush Current
4 A
Base Inrush Pulse
100 ms
Cross-comm Ports
X24, X25
Cross-comm Role
Master
Cross-comm Standard
IEEE 802.3
Engineering Compatibility
100Base-TX
Engineering Connector
RJ-45, 8-pin
Master Communication
SERCOS II
Safety Function
Safe Torque Off
Serial Interface
RS232
Serial Max Cable
15 m
Serial Max Rate
115 kBaud
Sto Connector
D-Sub, 9-pin, female
  • CSH013CSENNNNNNCCDL2SNNFW
  • CSH01 3C SE NNN NNN CCD L2 S NN FW
  • csh01.3c-se-nnn-nnn-ccd-l2-s-nn-fw
  • CSH1.3C-SE-NNN-NNN-CCD-L2-S-NN-FW

Frequently Asked Questions about CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW:

Q: How many analog input channels are available on the CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW controller?

A: The CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW offers 1 analog input channel for connecting external analog devices.

Q: How many analog output channels does the CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW controller provide?

A: There are 2 analog output channels included, which can be used for analog signal output to external equipment.

Q: What safety function is available on the CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW controller?

A: A Safe Torque Off (STO) safety function is included on this controller for enhanced operational security.

Q: What are the specifications of the serial interface on the CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW controller?

A: The serial interface on this model uses the RS232 standard and supports cable lengths up to 15 meters.

Q: What cross-communication standard does the CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW support?

A: IEEE 802.3 is the cross-communication standard supported by this controller for networked communication.


Internal Product Review

  • ‘‘The CSH01.3C-SE-NNN-NNN-CCD-L2-S-NN-FW is a Bosch Rexroth Indramat advanced controller built for precise motion systems, featuring SERCOS II master communication. Safe Torque Off adds valuable machine protection, and IEEE 802.3 cross-communication supports dependable controller coordination. An RJ-45 engineering interface streamlines commissioning, making this unit a strong choice for disciplined automation architectures.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo