4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW Bosch Rexroth Indramat

MPN: R911330540

No Tariffs On US Orders
  • Rated 4.5 (26 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
4 Minutes 43 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW belongs to the CSH Advanced Controllers series and supports SERCOS II control communication as well as SERCOS III master cross communication. This controller offers digital outputs rated at 24 VDC and 0.5 A, with two differential analog input channels and two analog output channels. It features Safe Motion safety technology and operates with a base power consumption of 8.5 W.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW control section belongs to the CSH Advanced Controllers series from Bosch Rexroth Indramat. It plugs into IndraDrive power modules to coordinate axis movement, fieldbus traffic, and machine-level safety in automated cells. By combining motion control, communication links, and local I/O on one card, it simplifies cabinet layouts and setup across a wide range of industrial automation tasks.

Power drawn by the controller itself is only 8.5 W, so thermal load inside the drive rack stays low. Command exchange with drives and higher-level PLCs is handled through SERCOS II, and that fiber-optic ring operates at up to 16 MBaud for cyclic data and real-time status. A copper service port rated at 100Base-TX supports setup over standard Ethernet tools. The card provides two programmable transistor outputs that can switch loads up to 24 VDC, 0.5 A. These outputs are suited for contactors or stack-light segments that require rapid state changes with a maximum pulse width of 100 ms. Feedback from motors is accepted over the IndraDyn, HIPERFACE, or 1 Vpp encoder interface, enabling absolute or incremental position capture. For local analog processing, the MA1 block offers two differential input channels, two voltage-scaled outputs, an input resistance of 1000 kΩ, and a 115 kBaud RS-232 service connector for legacy diagnostics.

System-level interaction continues through the integrated SERCOS III Master, allowing cross-communication between multiple drives without an external PLC gateway. When higher resolution is required, each MA1 output can update in steps as fine as 5 mV/inc, providing smooth setpoint profiles to external actuators. The controller’s hardware supports the certified Safe Motion functions, so speed, position, and torque monitoring can be executed directly on the drive. A form-C relay on the card can switch up to 24 VDC, 1 A for enable chains, and inrush current is limited to 4 A to prevent supply disturbances during power-up.

Base Power Consumption
8.5 W
Control Communication
SERCOS II
Cross Communication
SERCOS III Master
Digital Output Rating
24 VDC, 0.5 A
Encoder Interface
IndraDyn, HIPERFACE, 1 Vpp
Engineering Ethernet
100Base-TX
Ma1 Analog Inputs
2 Differential Channels
Ma1 Analog Outputs
2 Channels
Ma1 Input Resistance
1000 kΩ
Ma1 Output Resolution
5 mV/inc
Max Pulse Width
100 ms
Max Rs232 Rate
115 kBaud
Max Sercos Rate
16 MBaud
Relay Contact Rating
24 VDC, 1 A
Safety Technology
Safe Motion
Typ Inrush Current
4 A
  • CSH013CSEENSMA1CCDS2SNNFW
  • CSH01 3C SE ENS MA1 CCD S2 S NN FW
  • csh01.3c-se-ens-ma1-ccd-s2-s-nn-fw
  • CSH1.3C-SE-ENS-MA1-CCD-S2-S-NN-FW

Frequently Asked Questions about CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW:

Q: What communication protocols are supported by the CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW controller?

A: The CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW controller communicates using SERCOS II for control and SERCOS III Master for cross communication.

Q: Which encoder interfaces are available on the CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW?

A: This controller is equipped with an IndraDyn, HIPERFACE, 1 Vpp encoder interface for feedback and position detection.

Q: How many analog input and output channels does the MA1 module of the CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW provide?

A: Two differential analog input channels and two analog output channels are available with 5 mV per increment output resolution.

Q: What is the base power consumption of the CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW controller?

A: The base power consumption for this controller is rated at 8.5 W during standard operation.

Q: What type of safety technology is implemented in the CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW controller?

A: Safe Motion safety technology is included in this controller for advanced operational safety.


Internal Product Review

  • ‘‘The CSH01.3C-SE-ENS-MA1-CCD-S2-S-NN-FW from Bosch Rexroth Indramat is an advanced controller with SERCOS II control communication and SERCOS III master cross communication for high-speed, synchronized automation. Featuring Safe Motion safety technology and support for multiple encoder interfaces, the unit excels in precision motion control applications. This controller stands out for its versatile connectivity and reliable performance in demanding environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo