CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW Bosch Rexroth Indramat

MPN: R911334955

No Tariffs On US Orders
  • Rated 4.5 (20 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
6 Minutes 35 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW is part of the CSH Advanced Controllers series. It supports Sercos III master communication and uses 100Base-TX for the S3 link. The controller features a safety connector with D-Sub 9-pin female interface, Safe Motion technology, and dimensions of 241 mm height, 103 mm depth, and 49.5 mm width.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW is an advanced motion and safety controller produced by Bosch Rexroth Indramat within the CSH Advanced Controllers series. Installed in a drive cabinet, it coordinates feedback, fieldbus traffic, and safety signals so that servo drives operate in synchrony with higher-level automation systems. By merging communication and safety functions on one compact card, it streamlines axis integration for packaging machinery, assembly stations, and material-handling lines.

The controller’s analog command channel tolerates input swings of ±10 V, allowing direct connection to speed or torque setpoints from external sources. Internal electronics consume only 8.5 W, which minimizes heat load inside densely populated enclosures. Discrete outputs can source up to 1.1 A, supporting solenoid valves or relays without auxiliary amplifiers. The EN2 encoder interface is powered by 5.0 VDC and can draw up to 350 mA, supplying incremental encoders with stable logic power. Real-time drive coordination uses the Sercos III master channel, giving deterministic motion cycles and sub-microsecond synchronization across multiple axes.

Safety circuitry receives logic power from an ENS rail rated at 11.6 VDC with a maximum demand of 500 mA, and it distributes field power through a dedicated line held at 24 VDC. Cross-controller data exchange is handled by the CCD master interface, while general service diagnostics move over an S3 Ethernet link that follows the 100Base-TX standard. The SafeX safety connector uses a 9-pin female D-Sub plug, and the integrated protection concept meets the Safe Motion profile to supervise speed, position, and standstill conditions. Mechanical dimensions are 241 mm high, 49.5 mm wide, and 103 mm deep, so the module occupies little rack space while still providing front access for wiring and status LEDs.

Analog Input Range
±10 V
Base Power Draw
8.5 W
Cross Communication
CCD Master
Digital I/o Max Current
1.1 A
En2 Supply Current
350 mA
En2 Supply Voltage
5.0 VDC
Ens Supply Current
500 mA
Ens Supply Voltage
11.6 VDC
Master Communication
Sercos III
Overall Depth
103 mm
Overall Height
241 mm
Overall Width
49.5 mm
S3 Link Standard
100Base-TX
Safety Connector
D-Sub, 9-pin, female
Safety I/o Supply
24 VDC
Safety Technology
Safe Motion
  • CSH013CS3ENSEN2CCDS2SNNFW
  • CSH01 3C S3 ENS EN2 CCD S2 S NN FW
  • csh01.3c-s3-ens-en2-ccd-s2-s-nn-fw
  • CSH1.3C-S3-ENS-EN2-CCD-S2-S-NN-FW

Frequently Asked Questions about CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW:

Q: What is the analog input range supported by the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW controller?

A: The analog input range on the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW controller is ±10 V for precise signal integration.

Q: How much base power does the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW consume during operation?

A: The base power draw required for operation is 8.5 W on this model.

Q: Which master communication protocol is featured on the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW?

A: Sercos III is used as the master communication protocol in this controller.

Q: What kind of safety technology is included in this Bosch Rexroth controller?

A: Safe Motion technology is implemented for safety functions in the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW.

Q: What type of connector is used for the safety I/O on the CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW?

A: The controller uses a D-Sub, 9-pin, female connector for safety-related I/O connections.


Internal Product Review

  • ‘‘The CSH01.3C-S3-ENS-EN2-CCD-S2-S-NN-FW is a Bosch Rexroth Indramat advanced controller with Sercos III master communication and Safe Motion. CCD Master cross communication and a 100Base-TX S3 link provide clean network coordination for multi-axis systems. The ±10 V analog input and 8.5 W base power draw support efficient integration in motion-control cabinets.’’