CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW Bosch Rexroth Indramat
MPN: R911332230
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
59 Seconds
The Bosch Rexroth Indramat CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW is an advanced controller from the CSH Advanced Controllers series. It features two CCD ports with 100Base-TX standard and a CCD power draw of 1 Watt. The controller offers an analog input resistance of 160 kOhms and an analog output resolution of 19.5 mV per increment.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW is a single-axis control section produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. Installed in IndraDrive modular platforms, this unit executes motion sequences, signal conditioning, and network communication required for industrial automation cells. It coordinates feedback from sensors, distributes setpoints to power modules, and bridges fieldbus traffic between higher-level PLCs and local drives.
The two differential analog inputs present an impedance of 160 kΩ, minimizing loading on external transducers, and each step is resolved at 1.23 mV/inc to support fine position or pressure loops. Analog outputs update in 19.5 mV/inc increments so actuators receive precise command voltages. For real-time networking, the integrated CCD link follows the 100Base-TX Ethernet standard and is duplicated across two ports to permit daisy-chain wiring. That interface draws only 1 W, while the logic electronics consume 8.5 W, which helps limit heat inside the cabinet. Digital I/O groups can source up to 1000 mA in aggregate, and any single transistor output is limited to 500 mA to protect field wiring. A probe input recognizes edge events as short as 4 µs, enabling accurate capture of mark sensors during high-speed processes.
The service connection reaches up to 100 m when the engineering cable is routed to the RJ-45, 8-pin service jack, allowing remote access without relocating the controller. Relay contacts inside the section can switch DC 30 V at 1 A and are rated for a mechanical endurance of 1 × 108 cycles, making them suitable for frequent enable or brake tasks. Serial diagnostics are handled by the RS-232 port, which supports data exchange to a maximum of 115 kBaud over cable runs not exceeding 15 m. These interfaces provide analog control, Ethernet communication, relay switching, and serial diagnostics in one compact control section.
Frequently Asked Questions about CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW:
Q: What is the analog input resistance on the CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW controller?
A: The CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW controller features analog input resistance of 160 kΩ.
Q: What is the maximum RS232 baud rate supported by the CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW?
A: This controller supports a maximum RS232 baud rate of 115 kBaud for serial communication.
Q: How many CCD ports does the CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW controller provide and what standard do they use?
A: The CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW includes two CCD ports using the 100Base-TX standard.
Q: What is the analog output resolution of the CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW controller?
A: Analog output resolution for this controller is 19.5 mV per increment, allowing for precise output control.
Q: What is the relay contact rating on the CSH01.3C-NN-NNN-NNN-CCD-NN-S-NN-FW controller?
A: The relay contacts on this model are rated for a maximum of DC 30 V, 1 A.