CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW Bosch Rexroth Indramat
MPN: R911328827
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
19 Seconds
The Bosch Rexroth Indramat CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW is part of the CSH Advanced Controllers series and features a single-line control panel display. It offers Safe Torque Off as a safety function, supports encoder interfaces such as IndraDyn, HIPERFACE, 1 Vpp, and 5V-TTL, and has a base power consumption of 8.5 W. The controller has analog output ratings of 5 V and 1 mA, with a relay contact rating of 30 V DC at 1 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat produces the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW controller card for the CSH Advanced Controllers series. Mounted on an IndraDrive power stage, it interprets PLC commands, executes interpolation, and activates the Safe Torque Off channel to bring motors to a non-energized state when required. The board functions as the central motion coordinator in automated packaging, material handling, and printing machines.
The card’s analog section is designed for sensor feedback and actuator setpoints. Its input impedance of 160 kΩ minimizes current draw from delicate transducers, while each voltage output can source 1 mA at a maximum of 5 V, providing reference levels for external regulators or test points. When the module is energized, it draws a base inrush of 4 A. Once steady-state operation is reached, overall consumption stabilizes at 8.5 W, which helps with cabinet thermal planning. A single-line control-panel display allows parameter checks without an external HMI, and the STO input recognizes 24 V commands at 3 mA, linking the safety circuitry directly with machine relays.
The card also provides digital I/O and encoder interfaces. Each sourcing output delivers up to 500 mA, and groups of channels share a ceiling of 1000 mA, enabling direct actuation of contactors or indicator lamps without auxiliary amplifiers. The integrated relay carries loads to 30 V DC / 1 A, providing a dry-contact option for alarms. Feedback devices connect through the IndraDyn, HIPERFACE, 1 Vpp, and 5 V-TTL interface; the signal ports present 120 Ω termination to preserve line integrity, and the sensor supply furnishes 11.6 V at 500 mA for encoder electronics. When multiple drives must exchange position values in real time, the controller uses the IEEE 802.3 Master cross-communication channel to publish data over standard Ethernet wiring.
Frequently Asked Questions about CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW:
Q: What is the analog input resistance for the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW controller?
A: The CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW controller features an analog input resistance of 160 kΩ, suitable for a variety of analog sensor interfaces.
Q: What safety function is included in the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW controller?
A: This controller is equipped with a Safe Torque Off (STO) safety function for secure operation.
Q: What is the maximum digital output group current supported by the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW?
A: The digital output group on this unit supports a maximum current of 1000 mA, accommodating multiple output devices.
Q: Which encoder interfaces does the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW support?
A: The encoder interface is compatible with IndraDyn, HIPERFACE, 1 Vpp, and 5V-TTL, allowing flexible feedback device connectivity.
Q: What is the base power consumption of the CSH01.3C-NN-ENS-NNN-CCD-L2-S-NN-FW controller?
A: The base power consumption for this controller is 8.5 W, promoting energy-efficient operation.