CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW Bosch Rexroth Indramat
MPN: R911346757
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
49 Seconds
The Bosch Rexroth Indramat CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW is an advanced controller from the CSH Advanced Controllers series. It features Multi-Ethernet communication and supports encoder interfaces such as EnDat 2.1, 1 Vpp, and 5 V TTL. The controller offers analog input and output ranges from -10 to +10 V and has a base power consumption of 8.5 W.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW is a control section developed by Bosch Rexroth Indramat for the CSH Advanced Controllers series. It installs beside IndraDrive power units and supplies motion, logic, and communication services to automated machinery. By combining Multi-Ethernet networking, an MA1 analog module, and an EN2 encoder channel in one slot, the device coordinates servo axes, handles process I/O, and links the drive system with supervisory PLC or SCADA layers used in plant automation.
Its base electronics consume only 8.5 W, so cabinet cooling requirements remain modest. When the drive stack is energized, the section momentarily draws 4 A of inrush current, and this transient value must be considered when selecting fuses and contactors. For real-time traffic, the integrated port supports 100Base-TX Fast Ethernet and participates in Multi-Ethernet protocols as the cross-communication master. The MA1 front end accepts command voltages over a symmetrical span of ±10 V, enabling direct connection to speed or pressure regulators. Service and diagnostics can also be performed through the RS-232 socket, which operates at up to 115 kBaud for fast parameter access.
Signal reach is generous: the EN2 encoder interface maintains full resolution across shielded cables up to 75 m when sense conductors are present, and the ET real-time link can bridge 100 m between distributed drive cabinets. High impedance, specified at 1000 kΩ, on the MA1 inputs prevents measurable loading of external transducers, while the corresponding outputs supply 10 mA for actuator cards. Event capture inputs tolerate pulse widths no longer than 100 ms, a constraint that preserves timing accuracy in fast sequencing applications. Analog I/O expansion is available when additional process channels are required.
Frequently Asked Questions about CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW:
Q: What Ethernet compatibility does the CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW controller support?
A: The CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW controller supports 100Base-TX Ethernet compatibility for network connections.
Q: What is the Ma1 analog input range on the CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW?
A: This controller offers a Ma1 analog input range of ±10 V.
Q: What is the base power consumption of the CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW controller?
A: The base power consumption for this model is 8.5 W.
Q: What is the maximum RS232 cable length allowed on this controller?
A: The maximum cable length for the RS232 interface is 15 meters.
Q: What encoder interface options are available on the CSH01.3C-ET-EN2-MA1-CCD-NN-S-NN-FW controller?
A: This controller features an encoder interface supporting EnDat 2.1, 1 Vpp, and 5 V TTL.