CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911320079

No Tariffs On US Orders
  • Rated 4.5 (53 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and features SERCOS II control communication with a data rate of 16 MBaud. This controller supports analog input ranges of ±10 V, digital input ratings of 24 V at 3 mA, and includes an Ethernet-based engineering interface. Its power consumption is 11.5 watts and it offers RS232 serial connectivity.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW is a compact motion and logic controller in the CSH Advanced Controllers series from Bosch Rexroth Indramat. Installed in drive cabinets, it functions as the central processing unit that sequences axes, supervises fieldbus traffic, and bridges higher-level PCs with servo inverters on the plant floor. By combining deterministic bus control with local I/O processing, the device supports automated assembly, packaging, and material-handling lines that require precise coordination between multiple drives and peripheral sensors.

The controller accepts differential process voltages in a range of ±10 V, and its analog input has an input resistance of 160 kΩ, so connected transmitters are only lightly loaded. Command and feedback exchange with drives is handled over SERCOS II, and the interface supports a serial data rate of 16 MBaud for real-time cyclic telegrams. Discrete machine states enter through digital channels rated at 24 V / 3 mA, while an inrush limiter confines startup current to 4 A to protect cabinet fusing. An Ethernet-based engineering port supports configuration tasks, and the internal pulse generator can issue strobes down to 100 ms to synchronize external relays or pneumatic valves.

For outbound process control, an analog driver delivers 5 V / 1 mA, which is suitable for speed references to legacy frequency inverters. Cross-communication to other masters takes place over the plant network governed by IEEE 802.3, and this unit operates as the master so subordinate stations align their data to its cycle. High-side switching outputs rated at 24 V / 0.5 A can energize contactors directly, while a Form-A relay supports 24 VDC at 1 A for galvanically isolated signaling. Even with all channels active, the board draws only 11.5 W, which helps limit enclosure heat. Safety technology is not integrated, so any emergency stop logic remains external, and diagnostic access is available through the RS-232 interface.

Analog Input Range
±10 V
Analog Input Resistance
160 kohm
Analog Output Rating
5 V / 1 mA
Control Communication
SERCOS II
Cross Comm Role
Master
Cross Comm Standard
IEEE 802.3
Digital Input Rating
24 V / 3 mA
Digital Output Rating
24 V / 0.5 A
Engineering Interface
Ethernet-Based
Inrush Current
4 A
Max Pulse Width
100 ms
Power Consumption
11.5 W
Relay Contact Rating
24 VDC / 1 A
Safety Technology
None
Sercos Data Rate
16 MBaud
Serial Interface
RS232
  • CSH012CSENNNNNNCCDNNSNNFW
  • CSH01 2C SE NNN NNN CCD NN S NN FW
  • csh01.2c-se-nnn-nnn-ccd-nn-s-nn-fw
  • CSH1.2C-SE-NNN-NNN-CCD-NN-S-NN-FW

Frequently Asked Questions about CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW:

Q: What is the supported analog input range for the CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW controller?

A: The CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW supports a ±10 V analog input range.

Q: What type and speed of control communication does the CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW provide?

A: This controller uses SERCOS II communication with a data rate of 16 MBaud for control operations.

Q: What is the analog output rating for the CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW?

A: The analog output is rated at 5 V with a maximum output current of 1 mA.

Q: What kind of engineering interface does the CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW utilize?

A: The engineering interface on this controller is Ethernet-based, allowing for network integration.

Q: What is the relay contact rating for the CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW controller?

A: Relay contacts on this controller are rated for 24 VDC at 1 A.


Internal Product Review

  • ‘‘The CSH01.2C-SE-NNN-NNN-CCD-NN-S-NN-FW from the CSH Advanced Controllers line offers precise control communication through SERCOS II at a fast 16 MBaud data rate. With analog input support up to ±10 V and a high input resistance of 160 kΩ, signal integrity is well maintained. This controller stands out for its reliable performance and efficient networking capabilities.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo