CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW Bosch Rexroth Indramat

MPN: R911330208

No Tariffs On US Orders
  • Rated 4.5 (52 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
3 Minutes 59 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW is part of the CSH Advanced Controllers series and features a parallel interface for control communication with 16 inputs and 16 outputs. This controller provides analog output rated at 5 V, 1 mA and includes two encoder interfaces, with the first supporting standard encoder evaluation at a supply of 11.6 V and 500 mA, and the second supporting 5 V encoder evaluation at 350 mA. Base power consumption is 8.5 W and peak inrush current is rated at 4 A.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The motion control card CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW is built by Bosch Rexroth Indramat for integration into the CSH Advanced Controllers series. Installed in an IndraDrive system rack, it executes axis positioning, evaluates connected encoders, and exchanges time-critical data with higher-level PLCs. By combining real-time fieldbus supervision with integrated safety lockout, the card coordinates servo drives and peripheral sensors so automated machinery can follow deterministic movement profiles in packaging, handling, or assembly lines. Its role inside the control stack is to manage motion-related data flow while maintaining reliable interaction between drive functions and external machine signals.

The controller’s base consumption is 8.5 W, so cabinet thermal planning can be completed with minimal forced airflow. A typical inrush requirement of 4 A must be considered when power is first applied to the drive stack. The analog monitor channel delivers a calibrated output of 5 V, 1 mA for oscilloscope tracking or drive diagnostics. Digital exchange is handled through a parallel interface that presents 16 In / 16 Out lines, allowing fast handshaking with local sensors or actuators. For multi-axis synchronization, the card operates as a SERCOS III Master on cross-communication ports X24 and X25, which supports deterministic cycle timing across connected drives without requiring a separate bus coupler.

Two differential encoder inputs are provided. Channel one offers a supply of 11.6 V at 500 mA for standard encoder evaluation, while channel two supplies 5.0 V at 350 mA for 5 V encoder evaluation. Safe stop handling follows Stop Category 0, and a relay output rated at DC 24 V, 1 A can release or interrupt external contactors in accordance with that category. A programmable output pulse can be stretched up to 100 ms to match downstream logic timing. These functions support precise feedback capture and controlled drive-enable signaling, and they help keep external interlocks coordinated with the rest of the automation system.

Analog Output Rating
5 V, 1 mA
Base Power Consumption
8.5 W
Control Communication
Parallel Interface
Cross Comm Ports
X24, X25
Cross Communication
SERCOS III Master
Encoder 1 Current
500 mA
Encoder 1 Supply
11.6 V
Encoder 2 Current
350 mA
Encoder 2 Supply
5.0 V
Encoder Interface 1
Standard Encoder Evaluation
Encoder Interface 2
5 V Encoder Evaluation
Max Pulse Width
100 ms
Parallel Interface I/o
16 In / 16 Out
Relay Contact Rating
DC 24 V, 1 A
Starting Lockout
Stop Category 0
Typ Inrush Current
4 A
  • CSH012CPLENSEN2CCDL1SK1FW
  • CSH01 2C PL ENS EN2 CCD L1 S K1 FW
  • csh01.2c-pl-ens-en2-ccd-l1-s-k1-fw
  • CSH1.2C-PL-ENS-EN2-CCD-L1-S-K1-FW

Frequently Asked Questions about CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW:

Q: What is the analog output rating for the CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW controller?

A: The CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW features an analog output rated at 5 V and 1 mA.

Q: What type of control communication does the CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW support?

A: This controller uses a parallel interface for its control communication.

Q: How much base power does the CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW consume during operation?

A: The base power consumption for this unit is 8.5 W.

Q: How many digital inputs and outputs does the parallel interface provide on this controller?

A: There are 16 digital inputs and 16 digital outputs available on the parallel interface I/O.

Q: What is the relay contact rating of the CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW controller?

A: The relay contact on this device is rated for DC 24 V at 1 A.


Internal Product Review

  • ‘‘The CSH01.2C-PL-ENS-EN2-CCD-L1-S-K1-FW is a Bosch Rexroth Indramat advanced controller with Parallel Interface communication and 16 In / 16 Out I/O capacity. SERCOS III Master cross communication through X24 and X25 supports clean network integration in multi-axis systems. Stop Category 0 starting lockout stands out as a valuable safety feature for disciplined motion control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo