4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW Bosch Rexroth Indramat

MPN: R911324079

No Tariffs On US Orders
  • Rated 4.5 (41 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
3 Minutes 24 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW is part of the CSH Advanced Controllers series and includes a parallel interface communication module and support for cross communication. It provides 16 parallel digital inputs, 16 outputs, and features a starting lockout safety technology. The controller comes equipped with one analog input, two analog outputs, an EnDat 2.1 encoder interface, and an RJ-45 engineering port.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW control section belongs to the CSH Advanced Controllers series from Bosch Rexroth Indramat. As a pluggable drive controller module, it manages axis commands, handles feedback processing, and links motion logic with higher-level PLCs in automated machinery. Its integrated communication and signal-conditioning functions allow the drive platform to combine servo regulation and starting-lockout supervision within a compact control section.

It provides 16 parallel digital inputs for status signals and 16 parallel digital outputs for actuator commands, enabling direct bit-level exchange with external devices without additional I/O cards. For proportional process variables, the unit includes 1 analog input and 2 analog outputs, so it can read reference voltages and send continuous control signals to connected hardware. An internal communication module uses a parallel interface and works with two cross-communication ports, while the primary programming and diagnostics link uses an RS232 serial interface. A memory card slot accepts parameter backup media, and a single normally open relay contact can switch auxiliary loads directly.

Service communication is handled through 100Base-TX Ethernet on an RJ-45, 8-pin port. Motor feedback is received through an encoder interface that supports EnDat 2.1 / 1 Vpp / 5 V TTL, allowing incremental or absolute position data to be processed without adapter boards. Functional safety uses a starting-lockout circuit that expects a 24 V / 3 mA start lockout signal, and that logic can also be shared over the controller’s Option 3 cross-communication channel. When serial wiring is used, the permitted harness reaches 15 m serial cable length, and the two cross-communication ports support coordinated operation between axes.

Analog Inputs
1
Analog Outputs
2
Communication Module
Parallel Interface
Cross-comm Ports
2
Encoder Interface 1
EnDat 2.1 / 1 Vpp / 5 V TTL
Engineering Ethernet
100Base-TX
Engineering Port
RJ-45, 8-pin
Memory Card Slot
1
Option 3 Function
Cross Communication
Parallel Digital Inputs
16
Parallel Digital Outputs
16
Relay Contacts
1 N/O
Safety Technology
Starting Lockout
Serial Cable Length
15 m
Serial Interface
RS232
Start Lockout Signal
24 V / 3 mA
  • CSH012CPLEN2NNNCCDL1SNNFW
  • CSH01 2C PL EN2 NNN CCD L1 S NN FW
  • csh01.2c-pl-en2-nnn-ccd-l1-s-nn-fw
  • CSH1.2C-PL-EN2-NNN-CCD-L1-S-NN-FW

Frequently Asked Questions about CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW:

Q: How many analog input channels does the CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW controller support?

A: The CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW is equipped with 1 analog input channel.

Q: What type of communication module is included with this advanced controller?

A: This model features a Parallel Interface as its main communication module.

Q: How many parallel digital input channels are available on the CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW?

A: The controller offers 16 parallel digital inputs, allowing for extensive device connectivity.

Q: How many cross-comm ports are present on this controller model?

A: It provides two cross-communication ports, enhancing system integration options.

Q: What encoder interfaces are supported by the CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW controller?

A: For dual communication, the controller supports EnDat 2.1, 1 Vpp, and 5 V TTL encoder interfaces.


Internal Product Review

  • ‘‘The CSH01.2C-PL-EN2-NNN-CCD-L1-S-NN-FW is a Bosch Rexroth Indramat advanced controller that stands out with a parallel interface and EnDat 2.1 encoder support. Dual cross-comm ports and 100Base-TX engineering Ethernet make the unit well suited for coordinated drive networks and streamlined setup. Starting lockout safety adds valuable protection at the control level, making the controller a strong choice for disciplined automation platforms.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo