CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW Bosch Rexroth Indramat
MPN: R911315511
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
36 Seconds
The Bosch Rexroth Indramat CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW belongs to the CSH Advanced Controllers series. It features analog input range of ±10 V, analog input resistance of 160 kΩ, and analog output voltage of 5 V with a current of 1 mA. The controller offers engineering Ethernet at 100Base-TX and a Profibus connector with EIA-RS485 physical layer.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW control section belongs to the CSH Advanced Controllers series from Bosch Rexroth Indramat. It occupies the processor slot of an IndraDrive unit and coordinates motion, fieldbus, and feedback tasks for servo axes in automated machinery. By combining real-time processing with integrated network ports, the module acts as the interface between drive power electronics and higher-level PLC or PC systems. This layout allows command handling, communication, and encoder evaluation to remain inside the drive platform instead of relying on separate interface modules.
Its analog interface accepts a span of ±10 V, which is commonly used for velocity or torque commands, and the input path presents 160 kΩ of impedance so upstream sources are not heavily loaded. For actuator signaling, the board can source up to 1 mA at a fixed 5 V reference on the analog output channel. Discrete control is handled through 24 V logic, and each digital input recognizes that signal level with 3 mA of current consumption while digital outputs can switch external loads to supply rails. Configuration and diagnostics travel over an engineering Ethernet port that supports 100Base-TX signaling through an 8-pin RJ-45 connector, and the data link complies with IEEE 802.3 for reliable communication.
Within the drive rack, the controller draws only 8.5 W of base power, leaving more of the cabinet thermal budget available for the power modules. Integrated feedback support provides an encoder supply of 11.6 V at up to 500 mA, and that current level matches what is available on the digital output stage for solenoid or relay actuation. Position capture accuracy is supported by a probe channel that accepts trigger pulses as short as 4 µs. For fieldbus integration, the board carries a female 9-pin D-Sub that connects to a PROFIBUS-DP segment over the EIA-RS485 physical layer, and an internal repeater output of +5 V at 75 mA is available for line-powered bus extenders.
Frequently Asked Questions about CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW:
Q: What is the analog input range supported by the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW controller?
A: The analog input range for the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW controller is ±10 V.
Q: What is the digital input rating for the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW controller?
A: This model features digital input ratings of 24 V at 3 mA.
Q: Which communication standard does the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW support for cross communication?
A: The cross communication adheres to the IEEE 802.3 standard.
Q: What type of engineering connector is provided on the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW controller?
A: The engineering connector on this controller is an RJ-45, 8-pin interface.
Q: What is the base power consumption of the CSH01.2C-PB-ENS-NNN-CCD-NN-S-NN-FW controller?
A: This controller operates with a base power consumption of 8.5 W.