The Bosch Rexroth Indramat CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and features PROFIBUS control communication and a single-line display control panel. It offers encoder emulation for both Incremental and SSI encoders and uses an IEEE 802.3 Ccd standard. The controller has a maximum output frequency of 1 MHz through the MEM interface and a basic power consumption of 8.5 watts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW is a plug-in motion and logic controller from Bosch Rexroth Indramat and belongs to the CSH Advanced Controllers series. Installed in an IndraDrive power section, it supervises axis positioning, fieldbus traffic, and local I/O so that servo drives operate together within a plant-wide sequence. By combining communication, encoder processing, and application memory on a single card, the unit provides deterministic coordination for packaging lines, material handling cells, and similar industrial automation tasks. Placing these functions on one card reduces the need for separate interface modules inside the drive assembly.

Its basic electronics draw only 8.5 W, which keeps the internal load low and simplifies cabinet cooling. Motion commands pass through the PROFIBUS DP fieldbus, shown here as PROFIBUS, for deterministic cyclic data exchange with PLCs. The board also has a 100Base-TX engineering interface that follows the CCD standard IEEE 802.3, with the CCD role set as master for direct network management. Feedback hardware supplies encoders with 11.6 V DC at up to 500 mA, and it accepts incremental or SSI signals in standard mode. Operators interact through a single-line display on the control panel, which supports direct status review at the drive. No integrated safety technology is included, so safety functions must be handled by external devices.

A diagnostic RS-232 service port reaches a maximum speed of 115 kBaud and supports cable lengths up to 15 m for local access. The RS-232 connection is intended for short, local service links rather than long network runs. Application memory channels can transmit trigger signals at a peak frequency of 1 MHz, and these channels are intended for line runs up to 40 m. When discrete outputs must actuate solenoids or contactors, the onboard relay closes circuits rated at 24 V DC, 1 A. The relay output is suited to low-current switching tasks within the control cabinet.

Basic Power Consumption
8.5 W
Ccd Role
Master
Ccd Standard
IEEE 802.3
Control Communication
PROFIBUS
Control Panel
Single-Line Display
Encoder Emulation
Incremental And SSI
Encoder Evaluation
Standard
Encoder Supply Current
500 mA
Encoder Supply Voltage
11.6 V DC
Engineering Interface
100Base-TX
Mem Max Line Length
40 m
Mem Max Output Freq
1 MHz
Relay Contact Rating
24 V DC, 1 A
Rs232 Max Baud Rate
115 kBaud
Rs232 Max Cable Length
15 m
Safety Technology
None
  • CSH012CPBENSMEMCCDNNSNNFW
  • CSH01 2C PB ENS MEM CCD NN S NN FW
  • csh01.2c-pb-ens-mem-ccd-nn-s-nn-fw
  • CSH1.2C-PB-ENS-MEM-CCD-NN-S-NN-FW

Frequently Asked Questions about CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW:

Q: Which communication protocol does the CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW controller support?

A: The CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW controller supports PROFIBUS for control communication.

Q: What types of encoder emulation are offered by the CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW?

A: This model provides encoder emulation for both Incremental and SSI encoders.

Q: What is the maximum RS232 baud rate on the CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW?

A: The maximum RS232 baud rate supported by this controller is 115 kBaud.

Q: How much basic power does the CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW controller consume?

A: The basic power consumption for this controller is 8.5 W.

Q: What is the relay contact rating for the CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW controller?

A: The relay contacts on this controller are rated for 24 V DC at 1 A.


Internal Product Review

  • ‘‘The CSH01.2C-PB-ENS-MEM-CCD-NN-S-NN-FW is a Bosch Rexroth Indramat advanced controller with PROFIBUS communication and a 100Base-TX engineering interface. Standard encoder evaluation with incremental and SSI encoder emulation supports precise integration in motion-control systems. Basic power consumption of 8.5 W makes this controller an efficient choice for modern automation cabinets.’’