CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW Bosch Rexroth Indramat
MPN: R911318295
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
5 Seconds
The Bosch Rexroth Indramat CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and supports PROFIBUS fieldbus communication. It provides encoder emulation with both absolute and incremental signals, and supports EnDat 2.1, 1 Vpp, and 5 V TTL encoder outputs. The controller features a SERCOS III Master for cross communication and includes an Ethernet RJ-45 engineering port with 100Base-TX standard.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW is a configurable motion and I/O controller produced by Bosch Rexroth Indramat within the CSH Advanced Controllers series. It mounts in a Rexroth drive stack and supplies axis coordination, communication routing, and encoder processing for mid- to high-end automation cells. By combining fieldbus routing with integrated encoder emulation, the unit bridges drives, PLCs, and supervisory systems, allowing deterministic command exchange and position feedback across an equipment line.
The controller offers cross-communication through a SERCOS III Master interface for real-time drive networking, while machine-level data exchange is handled on the field side through PROFIBUS. Internal electronics draw only 19.5 W from the 24 V supply, minimizing panel heat. At power-up, the module briefly pulls 4 A, and this surge is limited to a 100 ms pulse so upstream supplies may stay compact. Engineering access uses an Ethernet RJ-45, 8-pin socket that follows 100Base-TX signaling, enabling parameter downloads from standard PCs without adapters. The PROFIBUS port is a D-Sub, 9-pin female connector, simplifying daisy-chaining on legacy installations. For feedback distribution, the board can emulate absolute or incremental encoders and reproduces EnDat 2.1, 1 Vpp, or 5 V TTL signal formats, allowing replacement of multiple external splitter cards.
Signal fidelity is supported by an emulation clock of 1 MHz and a maximum cable reach of 40 m between the controller and the first downstream device. When it powers external encoders, the supply delivers 350 mA at a regulated 5 V. Runs without sense lines may extend to 50 m, while installations that use sense conductors can reach 75 m before attenuation affects edge timing. The engineering port complies with automatic crossover detection, and the encoder emulator transmits both UVW and incremental channels so retrofit drives can accept synthetic feedback directly.
Frequently Asked Questions about CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW:
Q: What type of cross communication does the CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW support?
A: This controller utilizes SERCOS III Master for cross communication.
Q: Which fieldbus interface is offered on the CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW model?
A: The controller supports PROFIBUS connectivity via a D-Sub, 9-pin, female port.
Q: What are the maximum supported encoder cable lengths for this controller?
A: The maximum encoder cable length without sensing is 50 meters, and with sensing, it is 75 meters.
Q: What is the encoder supply voltage and current on the CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW?
A: This product provides encoder supply voltage at 5 V with a supply current of 350 mA.
Q: What is the rated power consumption for the CSH01.2C-PB-EN2-MEM-CCD-NN-S-NN-FW at 24 V?
A: The power consumption of this controller at 24 V is 19.5 W.