CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW Bosch Rexroth Indramat

MPN: R911321918

No Tariffs On US Orders
  • Rated 4.6 (60 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
6 Minutes 0 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW is part of the CSH Advanced Controllers series and features PROFIBUS-DP control communication. It offers a single-line display control panel, IEEE 802.3 cross communication standard, and an encoder interface with EnDat 2.1, 1 Vpp, and 5 V TTL support. The controller provides 2 differential analog input channels and 2 analog output channels, each with a ±10 V range and 12-bit input resolution.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW control section is produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. As a modular controller, it installs next to power inverters and coordinates motion functions within automated machinery. The board handles command preprocessing, manages local diagnostics, and passes status data to higher-level supervisors. This arrangement separates axis regulation from plant sequencing while retaining deterministic exchange across the drive bus. The card is intended for applications that require continuous, dependable communication between drives, encoders, and integrated safety circuits.

Fieldbus connectivity is delivered through PROFIBUS-DP, allowing cyclic process data to be exchanged over the D-Sub 9-pin female connector. For drive-to-drive coordination, the unit operates as the cross-communication master and follows the IEEE 802.3 Ethernet framework. The engineering port supports 100Base-TX, so configuration software can upload or download settings at 100 Mbit/s without an external switch. Feedback devices attach through the EnDat 2.1 / 1 Vpp / 5 V TTL encoder interface, and the integrated 5 V sensor supply powers the transducer directly, which helps reduce extra wiring. This layout supports orderly signal routing between the control section, the encoder, and the surrounding drive hardware.

The MA1 option board adds analog processing capabilities. It provides 2 differential channels for voltage measurement, and each channel accepts a span of ±10 V and digitizes signals with 12 bits of resolution for tasks such as torque or pressure command capture. Two matching analog outputs share the same voltage window for drive reference generation, which allows external devices to exchange low-level control signals with the system. Functional safety is handled through Safety Technology I/O; inputs are rated at 24 V / 3 mA, while solid-state outputs can source up to 24 V / 0.5 A for actuator release or enable lines. These functions reduce the need for separate I/O cards in compact cabinets and keep related control signals on the same module.

Control Communication
PROFIBUS-DP
Control Panel
Single-line display
Cross Communication Role
Master
Cross Communication Standard
IEEE 802.3
Encoder Interface
EnDat 2.1 / 1 Vpp / 5 V TTL
Encoder Supply
5 V
Engineering Interface
100Base-TX
Ma1 Analog Inputs
2 differential channels
Ma1 Analog Outputs
2 channels
Ma1 Input Range
±10 V
Ma1 Input Resolution
12 bits
Ma1 Output Range
±10 V
Profibus Connector
D-Sub, 9-pin, female
Safety Input Level
24 V / 3 mA
Safety Option
Safety Technology I/O
Safety Output Level
24 V / 0.5 A
  • CSH012CPBEN2MA1CCDS1SNNFW
  • CSH01 2C PB EN2 MA1 CCD S1 S NN FW
  • csh01.2c-pb-en2-ma1-ccd-s1-s-nn-fw
  • CSH1.2C-PB-EN2-MA1-CCD-S1-S-NN-FW

Frequently Asked Questions about CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW:

Q: What communication protocol does the CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW support for control integration?

A: This controller communicates with automation systems using the PROFIBUS-DP protocol.

Q: What type of control panel does the CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW include?

A: The CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW features a single-line display control panel for user interface.

Q: How many analog input channels are available and what are their specifications on the CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW?

A: This model offers two differential analog input channels with a ±10 V range and 12-bit resolution.

Q: What encoder interface options does the CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW provide?

A: EnDat 2.1, 1 Vpp, and 5 V TTL encoder signals are supported by this controller's encoder interface.

Q: What are the safety input and output levels on the CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW controller?

A: Safety Technology I/O with a 24 V input level at 3 mA and a 24 V output level at 0.5 A ensures proper safety signal integration.


Internal Product Review

  • ‘‘The CSH01.2C-PB-EN2-MA1-CCD-S1-S-NN-FW is a Bosch Rexroth Indramat advanced controller with PROFIBUS-DP control communication and a 100Base-TX engineering interface. The EnDat 2.1 / 1 Vpp / 5 V TTL encoder interface and 2 differential analog input channels support precise feedback and flexible signal processing. Safety Technology I/O with a 24 V / 0.5 A safety output makes the controller a strong choice for integrated motion control.’’