4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911315735

No Tariffs On US Orders
  • Rated 4.3 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
3 Minutes 1 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and supports Profibus communication with a maximum baud rate of 12 MBaud and a 9-pin D-Sub female connector. It features a ±10 V analog input range, digital input and output ratings of 24 V, and an analog output rated at 5 V and 1 mA. The controller includes an IEEE 802.3 standard cross communication and a 100Base-TX engineering interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW control section is manufactured by Bosch Rexroth Indramat as part of the CSH Advanced Controllers series. Installed on an IndraDrive base, this unit functions as the drive’s command processor, converting fieldbus data and feedback signals into precise current commands for servo axes used in automated assembly lines and packaging machines. It also manages the internal coordination of motion-related signals so the connected drive can respond accurately to changing operating conditions.

The controller samples motor phase currents every 62.5 µs, giving it tight current-loop regulation for high-bandwidth motion tasks. Two differential analog inputs accept control voltages in a range of ±10 V, and their input path has 160 kΩ of resistance to reduce loading on PLC analog cards. For actuator feedback, one analog output supplies 5 V / 1 mA. Twelve digital inputs are rated at 24 V / 3 mA, allowing direct connection to proximity switches and similar control devices. Data exchange with a service computer occurs over the engineering interface, which uses Ethernet 100Base-TX and follows the IEEE 802.3 standard. Additional sensor support includes an 8 V DC HSF supply, a 4 kHz resolver carrier, and an 18.2 Vpp resolver excitation signal.

A PROFIBUS-DP port communicates at up to 12 MBaud through a D-Sub, 9-pin female connector, forwarding setpoints received on the cross-communication bus to other drives. Eight sourcing outputs can switch loads up to 24 V / 0.5 A, allowing the control section to drive external signaling or interface circuits. For legacy controls, an RS-232 service port operates between 9.6-115 kBaud and supports cable lengths up to 15 m. A form-C relay contact is also available for safety chains at 24 V / 1 A, which adds a separate hardwired interface for machine status and interlock functions. This arrangement allows fieldbus communication, service access, and discrete I/O handling within the same control section.

Analog Input Range
±10 V
Analog Input Resistance
160 kΩ
Analog Output Rating
5 V / 1 mA
Cross Comm Standard
IEEE 802.3
Current Control Cycle
62.5 µs
Digital Input Rating
24 V / 3 mA
Digital Output Rating
24 V / 0.5 A
En1 Hsf Supply
8 V DC
En1 Resolver Frequency
4 kHz
En1 Resolver Supply
18.2 Vpp
Engineering Interface
100Base-TX
Profibus Baud Rate
12 MBaud
Profibus Connector
D-Sub, 9-pin female
Relay Contact Rating
24 V / 1 A
Rs232 Baud Rate
9.6-115 kBaud
Rs232 Cable Length
15 m max
  • CSH012CPBEN1NNNCCDNNSNNFW
  • CSH01 2C PB EN1 NNN CCD NN S NN FW
  • csh01.2c-pb-en1-nnn-ccd-nn-s-nn-fw
  • CSH1.2C-PB-EN1-NNN-CCD-NN-S-NN-FW

Frequently Asked Questions about CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW:

Q: What is the analog input voltage range supported by the CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW controller?

A: The CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW controller has an analog input range of ±10 V.

Q: What are the digital input ratings for the CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW controller?

A: This controller features a digital input rating of 24 V at 3 mA for each input.

Q: What is the Profibus baud rate capability of the CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW?

A: The supported Profibus baud rate on this model is 12 MBaud.

Q: Which engineering interface does the CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW controller utilize?

A: The engineering interface provided is 100Base-TX Ethernet.

Q: What is the relay contact rating for the CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW controller?

A: Relay contacts on this controller are rated for 24 V at 1 A.


Internal Product Review

  • ‘‘The CSH01.2C-PB-EN1-NNN-CCD-NN-S-NN-FW is a Bosch Rexroth Indramat advanced controller with PROFIBUS communication at 12 MBaud and a 100Base-TX engineering interface. A 62.5 µs current control cycle and IEEE 802.3 cross communication support give the controller fast response and dependable network integration. Strong connectivity and precise control make the controller a highly capable choice for demanding motion applications.’’