CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911327999

No Tariffs On US Orders
  • Rated 4.6 (53 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and features 1 analog input, 2 analog outputs, and a total of 4 combined I/O channels. It operates with a DC 24 V control supply, has a base power consumption of 8.5 W, and includes a SERCOS III Master for cross communication. The controller is equipped with two EnDat 2.1, 1 Vpp, or 5 V TTL encoder interfaces and supports a serial RS232 interface with a MiniDIN 8-pin port.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW control section is produced by Bosch Rexroth Indramat and belongs to the CSH Advanced Controllers series. It acts as the central motion processor inside IndraDrive systems. The unit handles axis coordination, feedback evaluation, and field-level communication for industrial automation cells such as packaging lines, material-handling gantries, and other synchronized machine platforms where multiple functions must operate together in a controlled sequence.

During standby the unit draws only 8.5 W, which minimizes panel heat and eases power-supply sizing. All logic circuits are fed from a separate DC 24 V supply so the controller can remain active while the main drive bus is de-energized. Network traffic moves through a SERCOS III Master interface, allowing deterministic exchange of setpoints and status with up to 32 slave drives. For position and velocity feedback, it provides 2 x EnDat 2.1 / 1 Vpp / 5 V TTL channels, letting the system use absolute optical encoders together with incremental sine-cosine or TTL devices on the same card. When control voltage is first applied, the input stage can momentarily draw 4 A, so the supply path must tolerate that short peak without nuisance trips. Programmable output pulses that supervise safety functions are limited to a maximum width of 100 ms to help prevent unintended latching of external relays.

The I/O header can source up to 1.1 A in total, supplying sensors or light loads without an extra supply module. Diagnostics are performed through a maintenance port that uses the RS232 protocol, and the physical connection is made through a keyed MiniDIN, 8-Pin socket for quick cable exchange. The card also carries one analog input, two analog outputs, and four combined digital channels, which supports straightforward integration of potentiometer references, torque monitor signals, and limit switches alongside the fieldbus network while keeping local signal wiring on the control section.

Analog Inputs
1
Analog Outputs
2
Base Power Consumption
8.5 W
Combined I/o Channels
4
Control Supply
DC 24 V
Cross Communication
SERCOS III Master
Encoder Interfaces
2 x EnDat 2.1 / 1 Vpp / 5 V TTL
Inrush Current
4 A
Max I/o Supply Current
1.1 A
Max Pulse Width
100 ms
Relay Contact
DC 24 V, 1 A
Serial Interface
RS232
Serial Port
MiniDIN, 8-Pin
  • CSH012CNNEN2EN2CCDNNSNNFW
  • CSH01 2C NN EN2 EN2 CCD NN S NN FW
  • csh01.2c-nn-en2-en2-ccd-nn-s-nn-fw
  • CSH1.2C-NN-EN2-EN2-CCD-NN-S-NN-FW

Frequently Asked Questions about CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW:

Q: What type of network cross communication is featured in the CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW controller?

A: The CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW supports SERCOS III Master cross communication.

Q: What control supply voltage does the CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW require?

A: This controller operates with a control supply voltage of DC 24 V.

Q: How many encoder interfaces are available on the CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW and what signal types do they support?

A: The model provides two encoder interfaces that support EnDat 2.1, 1 Vpp, and 5 V TTL.

Q: How many analog inputs and outputs does the CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW controller provide?

A: This controller is equipped with one analog input and two analog outputs.

Q: What type of serial interface and connector does this controller include?

A: The CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW features an RS232 serial interface with a MiniDIN 8-pin connection.


Internal Product Review

  • ‘‘The CSH01.2C-NN-EN2-EN2-CCD-NN-S-NN-FW is an advanced controller from the Bosch Rexroth Indramat CSH series, featuring SERCOS III Master cross communication and dual EnDat 2.1 encoder interfaces for precise feedback. With a control supply of DC 24 V and a combined I/O channel count of 4, this unit ensures reliable integration into automation systems. This controller stands out for applications requiring advanced communication and encoder feedback capabilities.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo