CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911322425

No Tariffs On US Orders
  • Rated 4.4 (63 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Available, Ships in 1-2 weeks

Current response time:
4 Minutes 52 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW is part of the CSH Advanced Controllers series and features CANopen and DeviceNet control communication. It comes with standard encoder evaluation and provides extension analog inputs and outputs with a ±10 V range. The controller includes a relay contact rating of 24 V DC at 1 A and uses a 100Base-TX engineering interface with RJ-45 connectors.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW plug-in control section is produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. Installed in an IndraDrive power section, it coordinates motion axes and field devices within an industrial automation cell. The board hosts real-time logic, encoder evaluation, and I/O expansion so that the connected drive can execute precise position, speed, and torque loops while also exchanging process data with higher-level control systems.

Fieldbus traffic is handled through CANopen and DeviceNet interfaces, allowing the controller to join either network without additional hardware. Two cross-communication sockets labeled X24 and X25 let multiple IndraDrive units share command and status words, and the board assumes the Master role in that local ring. Remote setup is possible over the engineering port, which supports 100Base-TX Ethernet and uses a shielded RJ-45, 8-pin connector. For legacy equipment, a separate RS232 serial link is provided, and it operates only for diagnostics so it does not interfere with deterministic bus cycles. Standard encoder evaluation on the card accepts incremental or absolute feedback devices and relays position data directly to the drive control.

The card sources digital signals up to 500 mA, which is enough to drive optical isolators or small relays on user panels, while the encoder supply delivers the same current at a regulated 11.6 V to power the sensing head. Two differential extension inputs and two voltage-following outputs share a symmetrical range of ±10 V, simplifying connection to external pressure sensors, potentiometers, or analog actuators. On-board reference outputs span 0 to +5 V for threshold generation and other low-level analog tasks. The relay contact, rated at 24 V DC, 1 A, can switch brakes or contactors directly without requiring an interposing relay stage.

Control Communication
CANopen, DeviceNet
Cross Comm Ports
X24, X25
Cross Communication Role
Master
Digital Output Current
500 mA
Encoder Interface
Standard Encoder Evaluation
Encoder Supply Current
500 mA
Encoder Supply Voltage
11.6 V
Engineering Compatibility
100Base-TX
Engineering Interface
RJ-45, 8-pin
Extension Analog Inputs
2 Differential
Extension Analog Outputs
2 Channels
Extension Input Range
±10 V
Extension Output Range
±10 V
On-board Output Range
0 to +5 V
Relay Contact Rating
24 V DC, 1 A
Serial Interface
RS232
  • CSH012CCOENSMA1CCDNNSNNFW
  • CSH01 2C CO ENS MA1 CCD NN S NN FW
  • csh01.2c-co-ens-ma1-ccd-nn-s-nn-fw
  • CSH1.2C-CO-ENS-MA1-CCD-NN-S-NN-FW

Frequently Asked Questions about CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW:

Q: Which communication protocols are supported by the CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW controller?

A: This controller supports CANopen and DeviceNet for control communication.

Q: How many analog input channels are available and what is their voltage range?

A: It features two differential extension analog inputs with a ±10 V input range.

Q: What type of connector is used for the engineering interface on this controller?

A: The engineering interface uses an RJ-45 connector with 8 pins.

Q: What is the on-board analog output voltage range of the CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW?

A: The on-board analog output range is 0 to +5 V.

Q: What are the voltage and current ratings of the relay contact output?

A: The relay contact is rated for 24 V DC and can handle up to 1 A.


Internal Product Review

  • ‘‘The CSH01.2C-CO-ENS-MA1-CCD-NN-S-NN-FW is a Bosch Rexroth Indramat advanced controller with CANopen and DeviceNet control communication. Standard encoder evaluation and an RJ-45 8-pin engineering interface support efficient commissioning and dependable signal handling. Master cross communication on X24 and X25 makes the controller a strong fit for coordinated automation architectures.’’