The Bosch Rexroth Indramat CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200 is part of the CSH Advanced Controllers series and supports control communication via SERCOS and a serial interface with RS232. It features an RJ-45, 8-pin engineering port supporting 100Base-TX Ethernet with a maximum cable length of 100 meters, and has a max group output current of 1000 mA. Relay contact is rated for DC 24 V at 1 Amp, and the digital input high and low levels are 15 V and 5 V respectively.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200 is a motion-logic controller card produced by Bosch Rexroth Indramat for integration within the CSH Advanced Controllers series. The card acts as the central processing and network node inside a modular drive system, coordinating servo axes through real-time bus communication and handling I/O preprocessing. Within industrial automation cells, it links field devices, converts machine-level commands into drive instructions, and maintains deterministic timing between motion tasks and sensor feedback.

In this variant, command exchange with drives occurs over SERCOS at the controller’s dedicated X20 and X21 fiber ports, maintaining synchronous cycles. The digital input block recognizes a logic high at 15 V and a logic low at 5 V, allowing direct connection to standard PLC signals. For service access, the board provides a 100Base-TX interface on an 8-pin RJ-45 socket. Configuration and diagnostics travel over CAT5e ITP cabling, and the link remains free of attenuation up to the specified 100 m distance. The Ethernet channel coexists with the SERCOS ring, giving a separate path for setup and status access without interrupting real-time traffic.

The output side is dimensioned for sensor power and relay switching tasks. A group of digital outputs can source up to 1000 mA, while any single point is limited to 500 mA; both limits protect field wiring from excessive load. When driving coils, the integrated suppressor dissipates 400 mJ of inductive energy to help prevent voltage spikes. The onboard relay can switch DC loads up to 24 V at 1 A, matching common cabinet control loops. For serial peripherals, the module offers an RS232 port with one addressable node, cable runs up to 15 m, and transfer rates up to 115 kBaud, enabling simple operator panels or barcode readers to share status data.

Control Communication
SERCOS
Digital Input High Level
15 V
Digital Input Low Level
5 V
Engineering Interface
100Base-TX
Engineering Port
RJ-45, 8-pin
Ethernet Cable Type
CAT5e ITP
Inductive Load Energy
400 mJ
Max Ethernet Cable Length
100 m
Max Group Output Current
1000 mA
Max Output Current
500 mA
Max Serial Cable Length
15 m
Max Serial Data Rate
115 kBaud
Relay Contact Rating
DC 24 V, 1 A
Sercos Connection
X20; X21
Serial Interface
RS232
Serial Node Count
1
  • CSH011NSE1RF1NNNNNNNNNNNFW/S200
  • CSH01 1N SE1 RF1 NNN NNN NNN NN FW/S200
  • csh01.1n-se1-rf1-nnn-nnn-nnn-nn-fw/s200
  • CSH1.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200

Frequently Asked Questions about CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200:

Q: What control communication protocol is used in the CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200 controller?

A: This controller features SERCOS as its control communication interface for real-time industrial networking.

Q: What type of engineering interface is available on this controller?

A: The engineering interface on this model is a 100Base-TX Ethernet port.

Q: What are the digital input high and low level voltages for the CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200?

A: Digital inputs on this controller recognize high levels at 15 V and low levels at 5 V.

Q: What are the specifications for the serial interface on this model?

A: The serial interface provided is RS232 with a maximum serial data rate of 115 kBaud and a maximum cable length of 15 m.

Q: Which ports are used for SERCOS connections on this controller?

A: SERCOS connections can be made via the X20 and X21 ports on the controller.


Internal Product Review

  • ‘‘The CSH01.1N-SE1-RF1-NNN-NNN-NNN-NN-FW/S200 is a Bosch Rexroth Indramat advanced controller with SERCOS control communication and a 100Base-TX engineering interface. An RJ-45 8-pin engineering port and RS232 serial interface support straightforward commissioning and dependable service access. Strong connectivity and clean integration make this controller a very capable choice for high-performance automation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo