CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW Bosch Rexroth Indramat

MPN: R911309724

No Tariffs On US Orders
  • Rated 4.5 (22 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
3 Minutes 28 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW is part of the CSH Advanced Controllers series and features 12 digital inputs and 8 digital outputs. This controller has an analog input resistance of 160 kOhm, an output resolution of 19.5 mV per increment, and a base power consumption of 7.5 W. The relay contact supports up to 1 ampere DC, and the En2 supply operates at 5.0 V with a supply current of 350 mA.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW is an automation controller module from Bosch Rexroth Indramat's CSH Advanced Controllers series. Installed in IndraDrive systems, it handles axis control, fieldbus communication, and safety stop logic for coordinated motion. Within an automation cabinet, it links sensors, encoders, and drive power stages so that position loops and machine sequencing can be executed without an external PLC. It is suited for coordinated axes where motion commands, feedback handling, and safe stopping need to remain in one control layer.

The analog front end accepts process voltages through an input path rated at 160 kOhm, which minimizes loading on connected transducers. That input stage supports stable signal handling when external sources are monitored directly by the controller. Each conversion step is resolved to 1.23 mV/inc for detailed feedback processing, and command signals leave the card with an output granularity of 19.5 mV/inc so drives receive smooth setpoints. Discrete control is supported by eight high-side drivers that supply up to 500 mA per channel. The MD1 option board also provides 12 opto-isolated digital inputs for limit switches or proximity sensors.

The EN2 encoder interface distributes 5 V logic power with a regulated 350 mA budget and accepts cable runs up to 50 m without sense leads; adding sense lines extends the allowable distance to 75 m. This supports encoder installation on larger machine layouts while keeping the feedback link on the controller. ENS safety feedback uses a 120 Ω termination and draws 500 mA at 11.6 V to monitor emergency-stop chains. Total heat dissipation is limited to 7.5 W, so forced-air cooling inside a drive rack is usually sufficient. For output to contactors or pilot valves, an onboard relay handles up to 1 A DC without an additional interface module.

Analog Input Resistance
160 kOhm
Analog Input Resolution
1.23 mV/inc
Analog Output Resolution
19.5 mV/inc
Base Power Consumption
7.5 W
Digital Output Current
500 mA
En2 Cable Length No Sense
50 m
En2 Cable Length With Sense
75 m
En2 Supply Current
350 mA
En2 Supply Voltage
5.0 V
Ens Input Resistance
120 Ohm
Ens Supply Current
500 mA
Ens Supply Voltage
11.6 V
Md1 Digital Inputs
12
Md1 Digital Outputs
8
Relay Contact Capacity
1 A DC
Starting Lockout
Stop Category 0
  • CSH011CSEENSEN2MD1L1SNNFW
  • CSH01 1C SE ENS EN2 MD1 L1 S NN FW
  • csh01.1c-se-ens-en2-md1-l1-s-nn-fw
  • CSH1.1C-SE-ENS-EN2-MD1-L1-S-NN-FW

Frequently Asked Questions about CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW:

Q: How many digital inputs does the CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW controller offer?

A: The CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW features 12 digital inputs, supporting multiple external signal connections for automation controls.

Q: How many digital outputs are available on the CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW?

A: This controller provides 8 digital outputs, allowing it to control various actuators or external devices directly.

Q: What is the analog input resistance value of this controller?

A: The analog input resistance is specified at 160 kOhm, ensuring compatibility with standard signal sources while minimizing current draw.

Q: How much base power does the CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW consume?

A: The base power consumption of the CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW is 7.5 W, helping reduce overall system energy usage.

Q: What is the relay contact capacity of the CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW controller?

A: The relay contact can handle up to 1 A DC, suitable for switching low-voltage loads within the system.


Internal Product Review

  • ‘‘The CSH01.1C-SE-ENS-EN2-MD1-L1-S-NN-FW is a Bosch Rexroth Indramat advanced controller with low 7.5 W base power consumption and Stop Category 0 starting lockout. MD1 onboard I/O with 12 digital inputs and 8 digital outputs supports clean machine interfacing and streamlined panel design. Accurate analog handling with 160 kOhm input resistance and 1.23 mV/inc input resolution makes the controller a strong fit for precise motion and automation tasks.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo