The Bosch Rexroth Indramat CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW is part of the CSH Advanced Controllers series. This controller supports SERCOS II control communication, provides a digital output current of 500 mA, and allows relay contact up to 1 Amp and 30 V DC. It features absolute SSI and incremental encoder emulation along with resolver and HSF encoder evaluation.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW controller section is manufactured by Bosch Rexroth Indramat for the CSH Advanced Controllers series. It acts as the central processing section in modular drive systems, coordinating motion axes and peripheral sensors by combining fieldbus communication, encoder handling, and discrete I/O resources. Installed inside IndraDrive power sections, this board manages positioning, speed, and torque loops for industrial automation machines.

Its network interface relies on SERCOS II, delivering synchronous telegram cycles for drive commands and status feedback. The board can source up to 500 mA on each digital output, enough to drive contactors or optically isolated relays without external amplifiers. The EN1 encoder connector supplies a regulated 8 V and has an input impedance of 10 kΩ, allowing direct connection of position transducers. For safety interlocks, the onboard relay carries up to 1 A at 30 V DC, so low-power circuits can be switched without auxiliary devices. High-speed capture of position data is supported by the MEM interface, which streams feedback with a maximum output frequency of 1 MHz for tight control at rapid cycle rates.

Signal quality is maintained over encoder leads because the MEM channel accepts cable runs up to 40 m without repeaters. For analog process values, the MA1 module offers two inputs and two outputs. Each output is trimmed in 5 mV steps, giving a resolution of 5 mV/inc, while the inputs reach a granularity of 1.23 mV/inc through the onboard converter. Filtering at the CPU front end is assisted by an input impedance of 160 kΩ, reducing loading on sensitive transducers. The controller can integrate resolver or HSF feedback, emulate absolute SSI as well as incremental signals, and use 1000 kΩ MA1 input paths with a range of industrial sensors without additional signal conditioners.

Control Communication
SERCOS II
Digital Output Current
500 mA
En1 Input Resistance
10 kΩ
En1 Supply Voltage
8 V
Encoder Emulation
Absolute SSI And Incremental
Encoder Evaluation
Resolver And HSF
Ma1 I/o Channels
2 In / 2 Out
Ma1 Input Resistance
1000 kΩ
Ma1 Output Resolution
5 mV/inc
Mem Max Cable Length
40 m
Mem Max Output Freq
1 MHz
Onboard Input Resistance
160 kΩ
Onboard Input Resolution
1.23 mV/inc
Onboard Output Resolution
19.5 mV/inc
Relay Contact Current
1 A
Relay Contact Voltage
30 V DC
  • CSH011CSEEN1MEMMA1NNSNNFW
  • CSH01 1C SE EN1 MEM MA1 NN S NN FW
  • csh01.1c-se-en1-mem-ma1-nn-s-nn-fw
  • CSH1.1C-SE-EN1-MEM-MA1-NN-S-NN-FW

Frequently Asked Questions about CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW:

Q: What control communication protocol does the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW use?

A: The CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW supports SERCOS II for control communication.

Q: What encoder emulation options are available on the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW?

A: This controller provides encoder emulation for both Absolute SSI and Incremental formats.

Q: What is the maximum cable length supported by the MEM function on the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW?

A: The maximum cable length for the MEM function on this unit is 40 meters.

Q: How many I/O channels are included with the MA1 module in the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW?

A: The MA1 I/O module features 2 input and 2 output channels.

Q: What are the relay contact current and voltage ratings on the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW?

A: Relay contacts on the CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW support up to 1 A current and 30 V DC.


Internal Product Review

  • ‘‘The CSH01.1C-SE-EN1-MEM-MA1-NN-S-NN-FW is a Bosch Rexroth Indramat advanced controller with SERCOS II control communication and absolute SSI/incremental encoder emulation. Resolver and HSF encoder evaluation pairs well with a 1 MHz MEM maximum output frequency, supporting accurate motion feedback and responsive signal handling. Strong interface versatility and a 40 m MEM maximum cable length make the controller a very capable choice for demanding automation systems.’’