The Bosch Rexroth Indramat CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW is an advanced controller in the CSH Advanced Controllers series, featuring SERCOS III control communication. It supports 16 expansion inputs and outputs, offers a Safe Torque Off safety function, and has an encoder interface compatible with EnDat 2.1, 1 Vpp, and 5 V TTL. The controller has a base power consumption of 7.5 W and supports cable lengths up to 75 meters with sense and 50 meters without sense.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW control section is produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. Installed in an IndraDrive inverter rack, it coordinates servo axes and manages integrated safety so that production lines, packaging machines, and material-handling cells receive synchronized motion commands and shutdown signals when required. It is intended for applications that need motion control and safety-related functions to operate within the same drive platform.

This unit’s base demand on the cabinet supply is 7.5 W. Two internal option channels add 6 W on the EN2 slot and 1 W on the MD2 slot, which helps with cabinet power and heat planning. Fieldbus traffic reaches the controller through SERCOS III, allowing deterministic communication with drives and PLCs. Feedback from motors is accepted over a multi-protocol interface that supports EnDat 2.1 / 1 Vpp / 5 V TTL, which allows use with different encoder types. The logic provides a regulated 5 V supply for encoders, so no separate external encoder power tap is required. Machine status signals enter through 16 digital expansion inputs, and the expansion outputs are arranged to support connected actuators in the same control structure.

Cable runs between the controller and servo drives can reach 75 m when sense conductors are used, or 50 m without them, which gives more flexibility in larger machine layouts. Functional safety is integrated through Safe Torque Off, which disconnects drive power when its two-channel circuit receives a permissive signal. That circuit requires a control level of DC 24 V / 3 mA and can energize external contactors up to DC 24 V / 1 A. SSI encoder support also allows absolute position detection for axes that do not use EnDat feedback.

Base Power Consumption
7.5 W
Cable Length With Sense
75 m
Cable Length Without Sense
50 m
Control Communication
SERCOS III
En2 Power
6 W
Encoder Interface
EnDat 2.1 / 1 Vpp / 5 V TTL
Encoder Supply
5 V
Expansion Inputs
16
Expansion Outputs
16
Input Grouping
2 x 8
Md2 Power
1 W
Output Grouping
4 x 4
Safety Function
Safe Torque Off
Ssi Encoder Support
Absolute Position Detection
Sto Input Level
DC 24 V / 3 mA
Sto Relay Rating
DC 24 V / 1 A
  • CSH011CS3EN2NNNMD2L2SNNFW
  • CSH01 1C S3 EN2 NNN MD2 L2 S NN FW
  • csh01.1c-s3-en2-nnn-md2-l2-s-nn-fw
  • CSH1.1C-S3-EN2-NNN-MD2-L2-S-NN-FW

Frequently Asked Questions about CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW:

Q: What type of control communication interface does the CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW controller use?

A: The CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW supports SERCOS III for control communication.

Q: What encoder interfaces are available on the CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW?

A: This controller features an encoder interface that is compatible with EnDat 2.1, 1 Vpp, and 5 V TTL encoder signals.

Q: What are the supported cable lengths for the CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW controller?

A: It has a maximum cable length of 75 meters when sense lines are used, and 50 meters without them.

Q: What safety function does the CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW controller include?

A: The safety function implemented is Safe Torque Off, which operates at a DC 24 V / 3 mA input level.

Q: How many expansion I/O points does the CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW controller offer?

A: There are 16 expansion inputs and 16 expansion outputs, organized into 2 groups of 8 inputs and 4 groups of 4 outputs.


Internal Product Review

  • ‘‘The CSH01.1C-S3-EN2-NNN-MD2-L2-S-NN-FW is a highly capable advanced controller with SERCOS III communication and Safe Torque Off for dependable motion applications. EnDat 2.1 / 1 Vpp / 5 V TTL encoder interface support, along with absolute position detection through SSI, gives feedback handling strong flexibility. A low 7.5 W base power consumption is a standout advantage.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo