The Bosch Rexroth Indramat CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW is part of the CSH Advanced Controllers series. It features 16 digital inputs and 16 digital outputs, supports PROFIBUS-DP master communication, and has Safe Torque Off safety functionality. The controller has two analog inputs and two analog outputs, both with a ±10 V range and 12-bit resolution.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW control section is produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. It plugs into modular drive racks and coordinates axis control, fieldbus exchange, and integrated safety. By combining encoder, analog, and high-density digital interfaces on one board, the unit acts as the command layer for industrial motion platforms that demand synchronized positioning, real-time data capture, and deterministic command distribution.

On the feedback side, an encoder port provides 12 VDC to incremental sensors, while an SSI channel offers 24 VDC at 0.2 A for absolute encoders. The MA1 option contributes 2 differential analog inputs and two analog outputs. Each input accepts signals within a ±10 V span, and the two outputs reproduce references across the same range. For plant networking, the controller relies on PROFIBUS-DP as its master interface, carried over the backplane. The MD2 extension supplies 16 sourcing digital inputs together with an equal number of transistor outputs, letting the section read limit switches and drive contactors without auxiliary relays. A dedicated RS-232 maintenance port supports data bursts up to 115 kBaud for service access.

Field wiring is simplified by the PROFIBUS port’s D-Sub, 9-pin connector, which mates directly with shielded cables. When higher-power circuits must be switched, the integrated relay accommodates 24 VDC, 1 A across its normally open contact. The safety package uses Safe Torque Off, enabling energy removal from the inverter through a monitored 24 VDC, 3 mA input. The MA1 converter uses a 12-bit A/D stage, and matching D/A resolution is used for the output channels. Logic voltage remains stable on the STO terminal, and paired MD2 outputs propagate status bits in real time to actuate pneumatic valves or signal towers during every cycle.

Encoder Supply
12 VDC
Ma1 Analog Inputs
2
Ma1 Analog Outputs
2
Ma1 Input Range
±10 V
Ma1 Input Resolution
12 bit
Ma1 Output Range
±10 V
Master Comm
PROFIBUS-DP
Md2 Digital Inputs
16
Md2 Digital Outputs
16
Profibus Connector
D-Sub, 9-pin
Relay Contact Rating
24 VDC, 1 A
Rs232 Max Rate
115 kBaud
Safety Function
Safe Torque Off
Ssi Encoder Supply
24 VDC, 0.2 A
Sto Input Rating
24 VDC, 3 mA
  • CSH011CPBENSMA1MD2L2SNNFW
  • CSH01 1C PB ENS MA1 MD2 L2 S NN FW
  • csh01.1c-pb-ens-ma1-md2-l2-s-nn-fw
  • CSH1.1C-PB-ENS-MA1-MD2-L2-S-NN-FW

Frequently Asked Questions about CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW:

Q: How many analog inputs are available on the CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW controller?

A: This controller features two analog inputs on the MA1 interface.

Q: What is the input and output voltage range for the MA1 analog channels?

A: The MA1 analog input and output ranges are ±10 V, suitable for precise control tasks.

Q: How many digital inputs are included with this controller?

A: Sixteen digital inputs are provided through the MD2 module on this model.

Q: Which communication protocol does the controller use for master comm?

A: The CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW uses a PROFIBUS-DP interface for master communication, allowing integration with industrial networks.

Q: Does this controller include a Safe Torque Off (STO) safety function?

A: The safe torque off (STO) function is supported, ensuring enhanced operational safety by disabling torque during emergency situations.


Internal Product Review

  • ‘‘The CSH01.1C-PB-ENS-MA1-MD2-L2-S-NN-FW is an advanced controller in the Bosch Rexroth Indramat CSH series, offering PROFIBUS-DP master communication and a D-Sub 9-pin connector for easy fieldbus integration. With 16 digital inputs and 16 digital outputs, along with two analog inputs and outputs at ±10 V and 12-bit resolution, this unit provides versatile interfacing options for automation systems. The Safe Torque Off safety function adds an important layer of protection, making this controller a strong choice for demanding industrial environments.’’