CSH01.1C-PB-EN2-NNN-NNN-S2-S-NN-FW

MPN: R911329481

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
    In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The CSH01.1C-PB-EN2-NNN-NNN-S2-S-NN-FW Advanced Control System is manufactured by Bosch Rexroth Indramat. This system operates with a PROFIBUS master communication configuration, its primary encoder option is EnDat 2.1/1 Vpp/TTL and it has two analog ouputs.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-PB-EN2-NNN-NNN-S2-S-NN-FW control section has a digital I/O with an E-Stop factory setting. The Bosch Rexroth advanced section comprises a relay contact with 1 x 106 switching actions at maximum time constant of load. The relay contact also has a maximum contact resistance of 1000 milli Ohms at minimum load. This section encompasses digital inputs/outputs adhering to IEC 61131, Type 1 specifications. The probe inputs of the product have an input current ranging between 2mA and 5mA. The device houses a PROFIBUS module that features a shield connection through a metalized connector housing and D-Sub mounting screws.

The section should not be plugged in or removed more than 20 times. This product is designed for storage in conductive packaging. This device must neither be damaged nor faulty when it is put to use. The drive controller featuring the unit has to be programmed before it is commissioned so that the motor performs the application-specific function. The PROFIBUS module in this control section receives and transmits data in adherence to EIA-RS485 standards. The product cannot be used when there are extreme temperature fluctuations. It is necessary to use a signal source with the least impedance at the first analog input for minimum linearity error.

This device is not meant to be put to use in a low-voltage mains-supplying residential area. The unit should be used only in the manner defined as appropriate by the manufacturer. It must be operated only if the application meets the required national EMC regulations. The section installation has to be executed taking all the general safety regulations and installation guidelines into consideration. Its spring terminal connections have to be done using stranded wires as much as possible. This advanced section with warranty backup for one year is shipped to your location through reputed freight carriers with a worldwide network.

Analog Outputs
2
Master Communication
PROFIBUS
Primary Encoder Option
EnDat 2.1/1 Vpp/TTL
  • CSH011CPBEN2NNNNNNS2SNNFW
  • CSH01 1C PB EN2 NNN NNN S2 S NN FW
  • csh01.1c-pb-en2-nnn-nnn-s2-s-nn-fw
  • CSH1.1C-PB-EN2-NNN-NNN-S2-S-NN-FW

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo