4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911314832

No Tariffs On US Orders
  • Rated 4.6 (47 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 43 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW is part of the CSH Advanced Controllers series and features PROFIBUS control communication and a RS232 serial interface. It includes two encoder interfaces supporting EnDat 2.1, 1 Vpp, and 5 V TTL formats, with an emulation output frequency of 1 MHz. The controller also provides a digital output current of 500 mA and a relay contact rating of 24 VDC at 1 A.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW control section is supplied by Bosch Rexroth Indramat for use within the CSH Advanced Controllers series. Installed in Rexroth drive racks, it acts as the central coordination unit that links motion axes with higher-level PLCs and field devices. The module manages axis logic, generates encoder emulation, and relays diagnostic data, so it serves as the interface between servo drives and the wider plant network in material-handling lines, packaging machines, and other automated cells.

For fieldbus traffic, the card offers PROFIBUS communication through a compact D-Sub 9-pin female connector, enabling cyclic exchange of setpoints and status words with drive controllers. Eight digital outputs share a common source that can supply up to 500 mA, allowing direct energizing of signal relays or indicator lamps. Position information can be retransmitted in Incremental / SSI format, and those square-wave channels can toggle at up to 1 MHz so high-resolution feedback reaches downstream devices without lag. Two hardware encoder sockets provide a total of 2 counting interfaces, permitting simultaneous processing of independent measuring systems while the emulation lines may extend 40 m without signal boosters.

Each encoder port can drive external receivers with a load of 35 ohms, and the integrated sensor supply delivers a regulated 5 V at 350 mA to power optical or magnetic transducers. When remote voltage-sense leads are used, the permitted feedback cable runs climb to 75 m, supporting large machines where drives are mounted far from motors. A single changeover relay contact rated for 24 VDC 1 A is present for ready-state signaling or fault routing. The board lacks integrated safety technology, so protective functions must be implemented in the main controller or external circuitry. An RS-232 maintenance port remains available for setup tasks and serial diagnostics.

Control Communication
PROFIBUS
Digital Output Current
500 mA
Emulation Formats
Incremental / SSI
Emulation Line Length
40 m
Emulation Output Freq
1 MHz
Encoder Interface Qty
2
Encoder Load Resistance
35 ohm
Encoder Signal Format
EnDat 2.1 / 1 Vpp / 5 V TTL
Encoder Supply Current
350 mA
Encoder Supply Voltage
5 V
Max Cable Length (no Sense)
50 m
Max Cable Length (sense)
75 m
Profibus Connector
D-Sub, 9-pin, female
Relay Contact Rating
24 VDC 1 A
Safety Technology
No Safety Technology
Serial Interface
RS232
  • CSH011CPBEN2EN2MEMNNSNNFW
  • CSH01 1C PB EN2 EN2 MEM NN S NN FW
  • csh01.1c-pb-en2-en2-mem-nn-s-nn-fw
  • CSH1.1C-PB-EN2-EN2-MEM-NN-S-NN-FW

Frequently Asked Questions about CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW:

Q: What communication protocol does the CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW controller support?

A: This model uses PROFIBUS for its control communication, allowing reliable fieldbus connectivity.

Q: How many encoder interfaces are available on the CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW controller?

A: The CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW features two encoder interfaces for connecting position feedback devices.

Q: What is the relay contact rating on the CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW?

A: Its relay contacts are rated for 24 VDC at a maximum of 1 A, supporting industrial relay switching.

Q: What is the maximum encoder cable length supported—with sense—on this controller?

A: The maximum cable length with sense is 75 meters, which helps maintain signal quality over longer distances.

Q: Which connector type is provided for the PROFIBUS interface on the CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW?

A: The PROFIBUS connection on this unit uses a D-Sub, 9-pin female connector for interface compatibility.


Internal Product Review

  • ‘‘The CSH01.1C-PB-EN2-EN2-MEM-NN-S-NN-FW is an advanced controller from the Bosch Rexroth Indramat CSH series with PROFIBUS control communication and dual encoder interfaces. Support for EnDat 2.1 / 1 Vpp / 5 V TTL encoder formats and RS232 service access gives this unit strong integration value in precision motion systems. A 1 MHz emulation output frequency further highlights fast, dependable feedback handling.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo