CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW Bosch Rexroth Indramat
MPN: R911315161
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
18 Seconds
The Bosch Rexroth Indramat CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW is part of the CSH Advanced Controllers series. It features an analog input resistance of 160 kiloohms and supports a relay contact current of 1 Amp. The controller has a base power consumption of 7.5 Watts and a digital output current rating of 0.5 Amps.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW is a compact control section created by Bosch Rexroth Indramat for the CSH Advanced Controllers series. It governs drive-based automation by processing analog feedback, issuing digital commands, and relaying fieldbus data to connected power stages. Within an installation, it acts as the central logic layer that times motion profiles, evaluates sensor values, and exchanges status information with supervisory PLCs. This arrangement lets one control section coordinate signal handling and communication tasks without adding a separate motion processor in the panel.
This controller draws a base power of 7.5 W during steady operation and can withstand an inrush of 4 A when the supply is first applied. Digital transistor outputs are rated for 0.5 A per channel, while the onboard relay channel can switch loads up to 1 A for auxiliary signaling. Analog monitoring circuits present an input resistance of 160 kΩ, allowing low-energy transmitters to be used, and their corresponding outputs are intended for a minimum load of 5 kΩ. Resolver feedback is accepted at a carrier frequency of 4 kHz with an excitation level suited to standard resolver sensing elements. The RS-232 service port supports speeds up to 115 kBaud, and cable runs can extend to 15 m without repeaters. A maximum pulse width of 100 ms is available on the fast counter, which helps the controller register short encoder gaps and similar brief events. That combination lets the unit manage discrete outputs, analog sensing, resolver feedback, serial service communication, and high-speed pulse evaluation from the same control section.
Module-level power budgets vary by installed interface. The PB fieldbus board dissipates 2 W, the EN1 Ethernet interface consumes 6 W, and the CCD option requires 1 W, so the total load depends on the fitted communication and option cards. Safety inputs are energized from an internal supply of 8 VDC at 250 mA, which removes the need for a separate external source for that circuit. These option-card losses add to the enclosure's thermal load alongside the base controller demand.
Frequently Asked Questions about CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW:
Q: What is the analog input resistance for the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW controller?
A: The analog input resistance of the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW is rated at 160 kΩ.
Q: What is the maximum digital output current available on the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW?
A: This controller offers a maximum digital output current of 0.5 A per channel.
Q: How much current can the relay contacts support on the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW?
A: The relay contacts on this model are rated to handle up to 1 A.
Q: What is the maximum RS232 cable length supported by the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW controller?
A: The CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW supports RS232 cable lengths up to 15 meters.
Q: What is the inrush current rating for the CSH01.1C-PB-EN1-NNN-CCD-L1-S-NN-FW controller?
A: The rated inrush current for this controller is 4 A.