4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW Bosch Rexroth Indramat

MPN: R911335417

No Tariffs On US Orders
  • Rated 4.4 (28 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 1-2 Days

Current response time:
5 Minutes 2 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW is an advanced controller from the CSH Advanced Controllers series. It features a single-line display, standard control panel, and supports encoder emulation up to 1 MHz output frequency and 40 meters line length. The controller provides a total output current of 1000 mA, digital input levels at 5 V off and 15 V on, and includes the Safe Torque Off safety function.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW belongs to the CSH Advanced Controllers series manufactured by Bosch Rexroth Indramat. This control section is installed in modular drive systems to handle axis processing, I/O supervision, and safety interlocking within automated machinery. By combining signal conditioning, encoder handling, and motion logic on one board, the module reduces cabinet space and simplifies the coordination between multiple IndraDrive power units.

An analog output resolution of 19.5 mV/Inc gives the board fine voltage steps for proportional valve or speed reference duties. Digital inputs are considered inactive below 5 V and reliably active above 15 V, a wide hysteresis that protects against field noise. Each fast-switching output channel can source up to 500 mA, while the shared rail is limited to 1000 mA, enabling mixed loads such as indicator lamps and small relays. The standard control panel offers a single-line display for local status checks without connecting external tools. Because control communication ports are not equipped on this variant, point-to-point diagnostics rely on the integrated RS-232 service socket and the indicated thresholds.

Option slot 3 is populated with encoder emulation; it reproduces feedback signals up to 1 MHz and can drive receivers over a maximum line length of 40 m using the dedicated 12-pin connector. The emulation stage is supplied from the encoder rail at 12 V, and the I/O domain can draw as much as 1.1 A from the internal power bus before derating. Serial commissioning runs at up to 115 kBaud over RS-232 cables no longer than 15 m, ensuring consistent parameter uploads. Safe Torque Off is implemented in hardware so drive power is cut instantaneously without relying on firmware-based stops.

Analog Output Resolution
19.5 mV/Inc
Control Communication
Not Equipped
Control Panel
Standard
Digital Input Off Level
5 V
Digital Input On Level
15 V
Display Type
Single-Line
Emulation Max Line Length
40 m
Emulation Max Output Freq
1 MHz
Encoder Supply Voltage
12 V
I/o Supply Max Current
1.1 A
Option 3 Function
Encoder Emulation
Output Current Per Channel
500 mA
Rs232 Max Baud Rate
115 kBaud
Rs232 Max Cable Length
15 m
Safety Function
Safe Torque Off
Total Output Current
1000 mA
  • CSH011CNNENSNNNMEML2SXPFW
  • CSH01 1C NN ENS NNN MEM L2 S XP FW
  • csh01.1c-nn-ens-nnn-mem-l2-s-xp-fw
  • CSH1.1C-NN-ENS-NNN-MEM-L2-S-XP-FW

Frequently Asked Questions about CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW:

Q: What is the analog output resolution of the CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW controller?

A: The CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW controller features analog output resolution of 19.5 mV per increment for precise signal control.

Q: What is the maximum line length supported for encoder emulation on the CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW?

A: This model supports encoder emulation with a maximum line length of 40 meters for signal transmission.

Q: What voltage levels define the digital input 'on' and 'off' states for this controller?

A: The digital input 'on' level is 15 V, while the 'off' level is 5 V for clear input state detection.

Q: What is the total maximum output current provided by the CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW controller?

A: The total output current available from the outputs is 1000 mA.

Q: What safety function is featured in the CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW?

A: Safe Torque Off is the designated safety function included in this controller.


Internal Product Review

  • ‘‘CSH01.1C-NN-ENS-NNN-MEM-L2-S-XP-FW is a Bosch Rexroth Indramat advanced controller with a standard control panel and Safe Torque Off protection. Encoder emulation with 1 MHz maximum output frequency supports precise signal handling in demanding motion applications. A single-line display keeps operation straightforward, making this unit a strong control-platform choice.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo