The Bosch Rexroth Indramat CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW is part of the CSH Advanced Controllers series and consumes 7.5 Watts of power. This controller features 16 digital inputs and 16 digital outputs through the MD2 module, with maximum digital output current for the S1 output at 0.5 Amps and I/O supply of 24 VDC. It also supports En2 encoder supply at 5.0 Volts and inrush current of 4 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW is an advanced control section produced by Bosch Rexroth Indramat for the CSH Advanced Controllers series. Installed in an IndraDrive power module, it orchestrates motion axes by processing encoder feedback, furnishing digital I/O, and issuing real-time drive commands that synchronize motors, sensors, and actuators in industrial automation lines. This control section serves as the logic and interface layer of the drive, linking field signals with closed-loop motion functions inside a compact module. It is suited for applications that require coordinated axis behavior, consistent feedback handling, and direct integration with machine wiring.

The EN2 encoder interface draws 350 mA from a dedicated 5.0 V rail and tolerates a load resistance of 35 Ω, allowing reliable differential signal reception from position transducers. At power-up, the control section presents an inrush of 4 A, which is relevant when sizing cabinet fusing and auxiliary supplies. Total internal demand stabilizes at 7.5 W during normal operation, which helps limit thermal rise inside compact enclosures. The EN2 sense lines can be clocked by an SSI channel that reaches a maximum of 1000 kHz, supporting fast absolute position updates for high-speed machinery. A maximum pulse width of 100 ms is supported for reference mark or latch inputs, so longer dwell signals can be captured without a timeout condition.

The MD2 expansion provides 16 digital inputs and an equal number of outputs, arranged in two input and four output groups so machine functions can be separated across different signal sections. Encoder sense cable length may extend up to 75 m when correct shielding is used, permitting remote feedback devices on gantries or transfer lines. The S1 terminal block distributes a control voltage of 24 VDC. Each transistor output can deliver 0.5 A, while the combined I/O rail is limited to 1.6 A and the relay contact is rated at 1 A for pilot-duty loads. These limits determine how many indicators, contactors, or brakes can be powered directly from the controller before external interface devices are needed.

En2 Encoder Current
350 mA
En2 Encoder Supply
5.0 V
En2 Load Resistance
35 Ω
En2 Max Cable Length (sense)
75 m
Inrush Current
4 A
Max Pulse Width
100 ms
Md2 Digital Inputs
16
Md2 Digital Outputs
16
Md2 Input Groups
2
Md2 Output Groups
4
Power Consumption
7.5 W
S1 Digital Output Current
0.5 A
S1 I/o Supply
24 VDC
S1 Max I/o Current
1.6 A
S1 Relay Contact Current
1 A
Ssi Max Clock Freq
1000 kHz
  • CSH011CNNEN2NNNMD2S1SNNFW
  • CSH01 1C NN EN2 NNN MD2 S1 S NN FW
  • csh01.1c-nn-en2-nnn-md2-s1-s-nn-fw
  • CSH1.1C-NN-EN2-NNN-MD2-S1-S-NN-FW

Frequently Asked Questions about CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW:

Q: How many digital inputs and outputs are available on the CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW controller?

A: The CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW controller supports up to 16 digital inputs and 16 digital outputs for versatile signal processing.

Q: What is the encoder supply voltage for the EN2 interface on this controller?

A: The EN2 encoder interface provides a supply voltage of 5.0 V to connected encoders.

Q: What is the maximum cable length supported for the EN2 encoder sense input?

A: This model can support a maximum EN2 encoder sense cable length of 75 meters.

Q: What is the maximum current available on each S1 digital output channel?

A: The S1 digital output channel can supply up to 0.5 A of current.

Q: What is the rated power consumption of this controller?

A: The power consumption for the CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW controller is rated at 7.5 watts.


Internal Product Review

  • ‘‘The CSH01.1C-NN-EN2-NNN-MD2-S1-S-NN-FW is an advanced controller built for precise automation tasks, with 16 digital inputs and 16 digital outputs for capable I/O management. The S1 interface supports a 24 VDC I/O supply and 1 A relay contact current, giving the unit solid integration value in control cabinets. Low 7.5 W power consumption makes this controller an efficient choice for modern machine control.’’