The Bosch Rexroth Indramat CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW is part of the CSH Advanced Controllers series and features a 100Base-TX Ethernet standard. Its analog input has a bandwidth of 1 kHz and resistance of 1000 kiloohms, while the analog output current is 10 mA with a load of 1 kiloohm. The controller has a base power draw of 7.5 watts and a maximum network cable length of 100 meters.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW belongs to the CSH Advanced Controllers series of modular drive control units. As a control section, it hosts analog conversion, safety outputs, and Ethernet, allowing a drive to coordinate motion axes and report status to higher-level PLCs. Internal encoder supply rails rated at 350 mA power feedback devices directly, while analog I/O pins accept reference voltages or generate command signals for the attached power section. The device mounts inside the drive stack with minimal panel wiring.

Each analog input accepts dynamic signals up to 1 kHz, so rapidly changing signals can be captured without aliasing. The input path presents a resistance of 1000 kΩ, and this high impedance helps prevent loading errors on connected transducers. Conversion resolution is 5 mV/inc, allowing the controller to detect small voltage differences for precise closed-loop regulation. An analog output can source up to 10 mA into a minimum load of 1 kΩ, so proportional valves or external recorders can be driven without additional buffers. For networked data exchange, the controller follows the 100Base-TX Fast Ethernet standard, and with twisted-pair cabling, segments can extend to 100 m without repeaters.

Electrical demand is modest, as the control electronics draw 7.5 W at standby, which helps limit cabinet heat rise. Option boards EN2, ET, and MA1 contribute additional draws of 6 W, 2.2 W, and 2 W respectively, figures that help calculate the complete supply budget for the drive stack. A power-up inrush of 4 A must be considered when sizing fuses, yet it decays after the internal capacitors charge. The safe switching channel can deliver up to 0.5 A to field devices, and the logic releases this current after a programmed startup pulse of 100 ms.

Analog In Bandwidth
1 kHz
Analog In Resistance
1000 kΩ
Analog In Resolution
5 mV/inc
Analog Out Current
10 mA
Analog Out Load
1 kΩ
Base Power Draw
7.5 W
En2 Power Draw
6 W
Encoder Load Resistance
35 Ω
Encoder Supply Current
350 mA
Et Power Draw
2.2 W
Ethernet Standard
100Base-TX
Inrush Current
4 A
Ma1 Power Draw
2 W
Max Network Cable
100 m
Safe Output Current
0.5 A
Startup Pulse
100 ms
  • CSH011CETEN2NNNMA1S2SNNFW
  • CSH01 1C ET EN2 NNN MA1 S2 S NN FW
  • csh01.1c-et-en2-nnn-ma1-s2-s-nn-fw
  • CSH1.1C-ET-EN2-NNN-MA1-S2-S-NN-FW

Frequently Asked Questions about CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW:

Q: What is the analog input bandwidth of the CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW controller?

A: This controller has an analog input bandwidth of 1 kHz, allowing for responsive analog signal processing.

Q: What Ethernet standard does the CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW controller support?

A: The Ethernet port on this model supports the 100Base-TX standard for network communication.

Q: What is the maximum network cable length for the CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW controller?

A: A maximum network cable length of 100 meters is supported by this controller's Ethernet port.

Q: What is the analog output current capability of the CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW?

A: The analog output on this controller can provide a current of up to 10 mA.

Q: What is the base power draw of the CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW controller?

A: This unit draws a base power of 7.5 W during operation.


Internal Product Review

  • ‘‘CSH01.1C-ET-EN2-NNN-MA1-S2-S-NN-FW is a Bosch Rexroth Indramat advanced controller with 100Base-TX Ethernet and a 100 m maximum network cable length. Analog input performance is especially well suited for precise automation tasks, with 1 kHz bandwidth and 5 mV/inc resolution. Strong connectivity and accurate signal handling make this controller a very capable choice for modern control architectures.’’