The Bosch Rexroth Indramat CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW is a control unit from the CDB Control Units series and supports up to two axes. It features SERCOS II communication, two ENS encoder interfaces with 12 V supply, and includes one analog input with an impedance of 160 kΩ, as well as two analog outputs. The unit has a typical inrush current of 6 A, power consumption of 9 W, and a relay contact rated for DC 24 V at 1 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW control section belongs to the CDB Control Units series manufactured by Bosch Rexroth Indramat. It is a plug-in controller that docks to IndraDrive power stages and supervises drive behavior for multi-axis automation lines. By combining signal conditioning, feedback processing, and fieldbus communication, the unit delivers coordinated motion commands to connected servo or spindle drives within packaging, printing, and material-handling systems. As a drive-integrated master, it merges local safety functions with real-time networking so that compact electrical cabinets can be used without external PLC racks.
Each drive channel is parameterized over the SERCOS II fiber-optic ring, while local reference values can be delivered through one analog input with an impedance of 160 kΩ. The controller routes position or torque demands back to the machine through two analog outputs, and each step at the port corresponds to 19.5 mV/inc; a maximum source current of 1 mA protects downstream cards. The embedded processor handles motion computation for 2 coordinated axes and draws only 9 W, which helps minimize cabinet heat. Dual ENS ports furnish incremental or absolute encoder feedback and supply transducers with isolated 12 V power.
During power-up, the module draws a typical inrush of 6 A for no longer than 60 ms, which helps prevent nuisance trips on branch protection. A 24 V auxiliary bus feeds the internal relay contact rated at 1 A DC for ready signaling, and it also serves the starting lockout input that monitors 3 mA acknowledgment from external safety circuitry. When the lockout is released, the unit can enable the power stage and still complies with Stop Category 0, so an emergency stop removes torque without delay or controlled deceleration.
Frequently Asked Questions about CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW:
Q: Which communication protocol does the CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW use?
A: The CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW supports SERCOS II communication for integration with compatible automation networks.
Q: How many axes can be managed by the CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW?
A: This control unit enables control of two axes, allowing you to operate dual-axis applications.
Q: How many analog outputs and what is their maximum current on the CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW?
A: The CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW provides two analog outputs with a maximum output current of 1 mA each.
Q: What safety stop category is featured in the CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW?
A: Stop Category 0 is implemented in this unit, ensuring immediate de-energization of actuators when the stop function is activated.
Q: What type and how many encoder interfaces are available on the CDB01.1C-SE-ENS-ENS-NNN-NNN-L1-S-K1-FW?
A: Two ENS encoder interfaces are present, each supplied with 12 V for standardized encoder connectivity.