4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW Bosch Rexroth Indramat

MPN: R911305633

No Tariffs On US Orders
  • Rated 4.6 (35 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW is part of the CDB Control Units series and features SERCOS II control communication with a standard control panel. It offers two encoder interfaces compatible with EnDat 2.1, 1 Vpp, and 5 V TTL types, and supports a total digital output group current of 1000 mA. The control unit includes Safety Technology I/O through an X41 D-Sub 9 connector and has a base power consumption of 9 W.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW is a plug-in control section manufactured by Bosch Rexroth Indramat for the CDB Control Units series. Installed on compatible power modules, it handles motion commands, feedback processing, and safety monitoring for industrial servo axes. Its role in an automation cabinet is to translate network telegrams into drive-level signals while coordinating encoder data and digital I/O, so the system can react to commands and feedback within the same compact hardware footprint.

This control section draws a base power of 9 W, so its internal electronics add only a minor thermal load inside the enclosure during operation. Command exchange with the host PLC uses the SERCOS II fiber-optic ring, providing deterministic timing for multi-axis synchronization. Operators interact through a standard control panel that plugs onto the front card edge. The board supports an encoder interface count of 2, and both channels use EnDat 2.1 / 1 Vpp / 5 V TTL signals for feedback. Each channel supplies 5.0 V at 350 mA and uses a 35 Ω load resistance to help prevent overcurrent faults. For actuator signaling, the card sources up to 500 mA per digital output, which is suitable for small relays or optocouplers.

Total sourcing capability over one output group is 1000 mA, allowing several devices to be powered at the same time without an external supply. On start-up, the circuitry can tolerate an inrush of 6 A before settling to steady-state draw. Pulse-shaped commands generated by the safety logic are limited to a maximum width of 60 ms to meet category timing tests. Safe shutdown and enabling are routed through an X41 D-Sub 9 connector that carries Safety Technology I/O, with channel inputs rated at 24 V / 3 mA and feedback outputs rated at 24 V / 0.5 A to drive contactors or status lamps without auxiliary interface boards.

Base Power Consumption
9 W
Control Communication
SERCOS II
Control Panel
Standard
Digital Output Current
500 mA
Digital Output Group Current
1000 mA
Encoder Interface Count
2
Encoder Interface Type
EnDat 2.1 / 1 Vpp / 5 V TTL
Encoder Load Resistance
35 Ohm
Encoder Supply Current
350 mA
Encoder Supply Voltage
5.0 V
Inrush Current
6 A
Max Pulse Width
60 ms
Safety Connector
X41, D-Sub 9
Safety Input Rating
24 V / 3 mA
Safety Output Rating
24 V / 0.5 A
Safety Technology
Safety Technology I/O
  • CDB011CSEEN2EN2NNNNNNS1SNNFW
  • CDB01 1C SE EN2 EN2 NNN NNN S1 S NN FW
  • cdb01.1c-se-en2-en2-nnn-nnn-s1-s-nn-fw

Frequently Asked Questions about CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW:

Q: What control communication protocol does the CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW use?

A: This model features SERCOS II as its control communication protocol.

Q: How many and what types of encoder interfaces does the CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW support?

A: The unit is equipped with two encoder interfaces supporting EnDat 2.1, 1 Vpp, and 5 V TTL signals.

Q: What is the maximum digital output group current for the CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW?

A: The maximum digital output group current supported is 1000 mA.

Q: What type of control panel does the CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW come with?

A: This control unit includes a standard control panel for user interactions.

Q: What safety connector and technology are included in the CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW?

A: It features a safety connector with X41, D-Sub 9, and supports Safety Technology I/O.


Internal Product Review

  • ‘‘The CDB01.1C-SE-EN2-EN2-NNN-NNN-S1-S-NN-FW is a Bosch Rexroth Indramat CDB control unit with SERCOS II communication and dual encoder interfaces. Support for EnDat 2.1 / 1 Vpp / 5 V TTL feedback and Safety Technology I/O gives the platform excellent motion feedback integration and dependable machine safety handling. A low 9 W base power consumption makes the controller an efficient choice for precise automation architectures.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo