CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW Bosch Rexroth Indramat
MPN: R911329073
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW is a control unit from the CDB Control Units series. It features a current control cycle of 125 microseconds and a base power consumption of 9 watts. The unit provides an analog output resolution of 19.5 millivolts per increment and supports a minimum Sercos cycle time of 1000 microseconds.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW belongs to the CDB Control Units series manufactured by Bosch Rexroth Indramat. As a plug-in control section for IndraDrive power modules, it coordinates servo axes, handles feedback signals, and exchanges data with higher-level controllers inside industrial automation cells. This model provides the signal conditioning, cycle timing, and safe-motion interfaces required for motion sequences that demand synchronized position and velocity loops. Because it plugs directly into the drive platform rather than operating as a standalone controller, it keeps axis control and feedback processing close to the power section.
The unit’s analog output path completes a conversion in 10 µs. This response time shows how quickly a drive command can be reconstructed as a voltage at the terminal. Each increment is quantized at 19.5 mV/inc, which is the smallest step that can be issued to analog-controlled components. Closed-loop torque or current regulation is refreshed every 125 µs, so the control section can correct disturbances eight thousand times per second. For encoder channels, the board presents 120 Ω of input resistance, which helps prevent signal reflections when long motor cables are used. It can accept differential sine, TTL, or RS-422 feedback up to 1000 kHz without loss of edge integrity or interpolation accuracy.
Total base consumption is 9 W, and the dedicated encoder conditioner adds another 6 W. These values help size the cabinet power supply and account for heat produced by the control section inside the enclosure. The sine encoder track is driven at 1.0 Vpp, while the sensor rails deliver 5.0 V at 350 mA to the transducer head. For real-time networking, the SERCOS interface can close telegram cycles down to 1000 µs, and its optical module draws 2 W. Relay contacts rated at DC 24 V / 1 A provide hardware enable functions, while logic inputs for the safe-motion channel are energized at 24 V and 3 mA. When the STO circuit is triggered, the output stage is limited to 1.6 A, and secondary outputs supply 24 V at 0.5 A for external status indicators.
Frequently Asked Questions about CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW:
Q: What is the analog output resolution of the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW control unit?
A: The analog output resolution on the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW is 19.5 mV per increment.
Q: What is the maximum supported encoder frequency on the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW?
A: This control unit supports encoder input frequencies up to 1000 kHz.
Q: What is the current control cycle duration for the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW?
A: The current control cycle on this model is set at 125 microseconds.
Q: What is the minimum Sercos cycle time available on the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW?
A: The minimum Sercos cycle time for this unit is 1000 microseconds.
Q: What is the relay contact rating for the CDB01.1C-SE-EN2-EN2-EN2-EN2-S2-S-NN-FW control unit?
A: Relay contacts on this unit are rated for DC 24 V at 1 amp.