CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW Bosch Rexroth Indramat
MPN: R911330195
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
16 Seconds
The Bosch Rexroth Indramat CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW control unit is part of the CDB Control Units series and supports two axes. It features SERCOS III communication and a serial RS232 interface, with a 24 V DC supply voltage and power consumption of 9 W. The unit offers analog output at 1 mA, digital output current up to 500 mA, and a relay voltage of 30 V DC with a safety starting lockout function.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW is a plug-in control section produced by Bosch Rexroth Indramat for mounting on power sections in the CDB Control Units series. Within an IndraDrive system, this module acts as the supervisory logic layer that coordinates motion commands, processes fieldbus data, and distributes I/O signals to connected drives and sensors. It is intended for multi-axis automation tasks where synchronized positioning, speed regulation, and integrated safety functions are required on assembly stations, packaging lines, and handling equipment.
Each control section powers up from a 24 V DC logic supply and draws up to 1.1 A during normal operation, resulting in a heat dissipation of 9 W, so ventilation demands on the cabinet remain modest. Two independent processing channels give the unit an axis count of 2, allowing synchronous interpolation between drives. Real-time motion commands and parameter downloads are exchanged over the SERCOS III fiber-optic ring, while a non-isolated serial port supports local programming. For local actuation, the board provides eight sourcing outputs that can switch loads up to 500 mA each, plus analog outputs that deliver 1 mA or 5 V signals for proportional valves, recorders, or transducers. A maximum output pulse width of 60 ms supports latch or kick functions on pneumatic valves.
System integration options expand through the built-in RS232 maintenance interface, which can stream diagnostic traces at up to 115 kbit/s without occupying the real-time bus. Event capture accuracy is enhanced by a probe channel with a 1 µs response that accepts sensor currents of 3 mA, ensuring precise edge recognition for print mark or registration tasks. During startup, the backplane can experience an inrush current of 6 A, but once steady, relay contacts rated for 1 A at 30 V DC handle field isolation. A Starting Lockout function prevents unintended drive enable until logic prerequisites are met when power or communications are restored.
Frequently Asked Questions about CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW:
Q: How many axes can the CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW control?
A: The CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW supports control of two axes simultaneously.
Q: What communication protocol does the CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW use?
A: This unit features SERCOS III communication for its data transfer functions.
Q: What is the maximum digital output current for the CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW?
A: The digital outputs on this control unit provide up to 500 mA of current.
Q: What supply voltage does the CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW operate on?
A: The supply voltage required for this control unit is 24 V DC.
Q: What safety function is available on the CDB01.1C-S3-NNN-NNN-NNN-NNN-L1-S-K1-FW?
A: A starting lockout is provided as the integrated safety function on this model.