The Bosch Rexroth Indramat CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW is part of the CDB Control Units series and uses SERCOS III for control communication. This unit has two probe inputs, a relay contact rating of 24 V DC at 1 Amp, and features a starting lockout safety function. It draws 9 Watts from a 24 V power supply and includes dual Ma1 channels with 12-bit resolution.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW belongs to the CDB Control Units series manufactured by Bosch Rexroth Indramat. It is a plug-in control section intended for coordinating drive functions within multi-axis automation cells. By hosting communication, safety, and low-voltage control hardware on one board, the unit streamlines operation of IndraDrive power sections and provides a standardized interface for logic, feedback, and peripheral signals.

The control section exchanges cyclic data over SERCOS III, so deterministic position and process information traverse the real-time Ethernet ring without separate fieldbus hardware. Internal electronics draw only 9 W from the 24 V control supply during normal operation, yet a brief inrush of 6 A occurs when power is first applied. A dedicated acknowledgment rail supplies actuators connected to the L1 terminal, and this rail is limited to DC 24 V / 1 A while being monitored for short-circuit events. The logic senses external ready signals through the L1 control line, which expects 24 V at 3 mA, and routes them through an unshielded D-Sub header so cabinet wiring remains compact.

I/O expansion is handled by the MA1 module, which offers 2 inputs and 2 outputs with a 12-bit resolution. Its digital outputs can generate pulses up to 60 ms for valve or gate triggering, and two probe inputs capture edge-aligned position marks for simple registration tasks. The S3 real-time ports terminate on a RJ-45, 8-pin connector and accept CAT5e ITP cabling, which simplifies network daisy chains across the drive rack. Command acknowledgment on the L1 side uses a D-Sub, 9-pin female plug that mirrors the pinout of legacy CDB versions. A built-in safety circuit provides Starting Lockout, which prevents unintended motion until the enable sequence is completed.

24v Power Draw
9 W
Control Communication
SERCOS III
Inrush Current
6 A
L1 Ack Supply
DC 24 V / 1 A
L1 Connector
D-Sub, 9-pin female
L1 Control Signal
24 V / 3 mA
Ma1 Channel Count
2 In / 2 Out
Ma1 Resolution
12 bit
Max Pulse Width
60 ms
Probe Inputs
2
Relay Contact Rating
DC 24 V / 1 A
S3 Cable Type
CAT5e ITP
S3 Connector
RJ-45, 8-pin
Safety Function
Starting Lockout
  • CDB011CS3NNNNNNNNNMA1L1SNNFW
  • CDB01 1C S3 NNN NNN NNN MA1 L1 S NN FW
  • cdb01.1c-s3-nnn-nnn-nnn-ma1-l1-s-nn-fw
  • CDB1.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW:

Q: What type of control communication does the CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW support?

A: The CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW uses SERCOS III for control communication.

Q: What connector type is provided for the L1 interface on this model?

A: The L1 connector is a D-Sub, 9-pin female type for secure connections.

Q: How many probe inputs does the CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW offer?

A: There are two probe inputs available on the CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW control unit.

Q: What is the resolution of the MA1 channel in this control unit?

A: The MA1 channel provides a resolution of 12 bits for precise analog operations.

Q: What safety feature is included in the CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW control unit?

A: The safety function for this model is a starting lockout feature to prevent unintended operation.


Internal Product Review

  • ‘‘The CDB01.1C-S3-NNN-NNN-NNN-MA1-L1-S-NN-FW is a Bosch Rexroth Indramat CDB control unit designed for precise machine control with SERCOS III communication. CAT5e ITP support with an RJ-45, 8-pin connector gives the S3 interface clean network integration. The MA1 channel configuration of 2 In / 2 Out and 12-bit resolution make this unit a strong choice for accurate signal handling.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo