CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW Bosch Rexroth Indramat
MPN: R911334764
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
48 Seconds
The Bosch Rexroth Indramat CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW is part of the CDB Control Units series and uses Sercos III as its communication protocol with an RJ-45 (8-pin) connector. It offers dual encoder feedback supporting IndraDyn, HIPERFACE, 1Vss, and TTL, and features a single-line display. This control unit supports 2 analog inputs and 2 analog outputs at ±10 V with 12-bit resolution, and comes with the Safe Motion safety function.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW control section is produced by Bosch Rexroth Indramat within the CDB Control Units series. It is installed in modular drive systems to coordinate axis functions, route feedback, and deliver fieldbus connectivity between servo inverters and the higher-level PLC in industrial automation. A single-line display provides local operator feedback and shows status codes during startup and runtime.
This version uses a RJ-45 (8-pin) connector to join the drive ring, and the interface carries the deterministic Sercos III protocol so cycle times stay consistent. For cabling, the manufacturer specifies CAT5e ITP twisted pair to maintain signal integrity over the Ethernet-based bus. The control section powers sensors and optocouplers through a field supply of DC 19-30 V with a ceiling of 1.1 A, eliminating the need for an external auxiliary supply. Encoder position data enters through a D-Sub 15 female socket, and two identical channels accept IndraDyn, HIPERFACE, 1Vss, or TTL formats so redundant feedback devices can be wired without additional interface cards.
Axis-specific analog processing is handled by the MA1 option card. It offers 2 differential ±10 V inputs for torque or speed commands and two ±10 V outputs with 12-bit resolution for feedback to legacy controllers. The encoder rails are energized at 12 V to match the requirements of incremental and absolute transducers connected on either feedback channel. Network monitoring over standard Ethernet is possible through the built-in 100Base-TX port, allowing service laptops to access diagnostic pages without disturbing the real-time fieldbus. Functional safety is integrated, and the unit supports the Safe Motion feature set so certified stop and limited-speed modes can be executed directly in the drive, reducing external wiring.
Frequently Asked Questions about CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW:
Q: What communication protocol does the CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW unit use?
A: The CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW supports Sercos III communication protocol via an RJ-45 (8-pin) connector.
Q: What type of analog inputs are available on the CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW?
A: This control unit features 2 differential ±10 V analog inputs for signal processing.
Q: Which encoder feedback types does the CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW support?
A: The device offers encoder feedback options including IndraDyn, HIPERFACE, 1Vss, and TTL for both available encoder connectors.
Q: What is the resolution of the analog input and output channels on the CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW?
A: It provides 12-bit resolution on its MA1 analog input and output channels.
Q: What safety function does the CDB01.1C-S3-ENS-ENS-NNN-MA1-S2-S-NN-FW provide?
A: The safety function offered in this model is Safe Motion, supporting enhanced machine safety.