4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911322426

No Tariffs On US Orders
  • Rated 4.6 (37 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
6 Minutes 16 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW belongs to the CDB Control Units series and has a base power consumption of 9 watts. It provides an inrush current of 6 amps with an inrush pulse width of 60 ms and supports output currents of up to 1000 mA per group and 500 mA per point. The control unit features an integrated output resolution of 19.5 mV/inc and a probe input accuracy of 1 microsecond.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat manufactures the CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW, a plug-in control card in the CDB Control Units series. Installed in IndraDrive amplifier stacks, it coordinates command processing, encoder evaluation, and discrete field wiring for industrial motion axes. The board translates higher-level PLC instructions into precise drive signals, enabling synchronized positioning and speed control across packaging, material-handling, and assembly machinery. Its layout allows control functions, feedback handling, and local signal exchange to remain on a single compact module inside the drive system.

The electronics have a base dissipation of 9 W, so cabinet ventilation demands stay moderate during normal operation. Logic power is supplied on the EN2 rail at 5.0 V, and the card draws up to 350 mA from that source; this line feeds DSP cores and memory used for motion tasks. Auxiliary circuitry is supported by an ENS rail rated at 11.6 V, which carries peripheral loads such as status LEDs and small relays. Startup protection is handled by an internal limiter that allows an inrush of 6 A without damaging upstream breakers. Each digital output group can source 1 A in total, while individual points are restricted to 500 mA to help prevent conductor overheating during fault conditions.

After power is applied, the inrush event is confined to a duration of 60 ms, which helps limit stress on filter capacitors and related supply components. Driver transistors absorb up to 400 mJ of inductive load energy, allowing direct actuation of pneumatic valves or clutches without separate suppression hardware in many installations. For analog precision, the integrated converter produces an output granularity of 19.5 mV/inc, and the MA1 input channel handles feedback signals with a bandwidth of 1 kHz. The card also supports accurate timing for probe signals and stable interfacing with connected field devices, which helps the drive respond cleanly to machine events and feedback changes.

Base Power Consumption
9 W
En2 Supply Current
350 mA
En2 Supply Voltage
5.0 V
Ens Supply Current
500 mA
Ens Supply Voltage
11.6 V
Inductive Load Energy
400 mJ
Inrush Current
6 A
Inrush Pulse Width
60 ms
Integrated Output Resolution
19.5 mV/inc
Ma1 Input Bandwidth
1 kHz
Ma1 Input Resistance
1000 kΩ
Ma1 Output Resolution
5 mV/inc
Output Current Per Group
1000 mA
Output Current Per Point
500 mA
Probe Input Accuracy
1 µs
Relay Capacity
1 A
  • CDB011CS3ENSENSEN2MA1NNSNNFW
  • CDB01 1C S3 ENS ENS EN2 MA1 NN S NN FW
  • cdb01.1c-s3-ens-ens-en2-ma1-nn-s-nn-fw
  • CDB1.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW:

Q: What is the base power consumption of the CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW control unit?

A: The CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW has a base power consumption of 9 W during operation.

Q: What is the integrated output resolution of this control unit?

A: This model supports an integrated output resolution of 19.5 mV/inc for precise control outputs.

Q: What is the inrush current and pulse width for the CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW?

A: The maximum inrush current for the unit is 6 A, with an inrush pulse width of 60 ms.

Q: What is the output current specification per group and per point on this unit?

A: Each output group can deliver up to 1000 mA of current, while individual points are limited to 500 mA.

Q: What is the probe input accuracy for this Bosch Rexroth Indramat control unit?

A: The probe input on this unit has an accuracy of 1 microsecond, supporting high-precision inputs.


Internal Product Review

  • ‘‘The CDB01.1C-S3-ENS-ENS-EN2-MA1-NN-S-NN-FW is a Bosch Rexroth Indramat CDB control unit with efficient 9 W base power consumption and a manageable 6 A inrush current. MA1 signal handling appears well tuned for precise control, pairing 1 kHz input bandwidth with 5 mV/inc output resolution. This unit presents as a strong choice for automation systems, especially with 1 µs probe input accuracy.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo