CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911320986

No Tariffs On US Orders
  • Rated 4.6 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 1 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW is part of the CDB Control Units series and has a typical power consumption of 34 Watts with a typical inrush current of 6 Amps. It supports analog output voltages of 5 Volts with a resolution of 19.5 mV per increment and features Sercos III ports compliant with IEEE 802.3 on an RJ-45 8-pin connector.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat supplies the CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW control unit as part of its CDB Control Units series. This modular unit acts as the command layer inside IndraDrive inverter stacks. It interprets fieldbus traffic and generates drive-ready signals for servo axes in automated machining, packaging, and material handling lines.

The unit provides two analog outputs, and each channel can drive loads down to 5 kΩ. Its DAC resolution of 19.5 mV/inc supports fine speed or torque references. These outputs swing up to 5 V, letting the controller interface with typical 0 to 5 V drive circuits. For binary signaling, every digital output can sink or source 500 mA, enabling direct actuation of relays or optocouplers without external amplifiers. A built-in RS-232 maintenance port streams parameter data at up to 115 kBaud, simplifying bench setup. The same port accepts cables up to 15 m long, while pulse-capture inputs register events down to 4 µs on probe type 2 and 200 µs on probe type 3. A maximum commanded pulse may last 60 ms without overrun.

Group limitation protects field wiring, and the combined current of the digital outputs is capped at 1000 mA so total thermal dissipation remains predictable. Feedback from resolver channel En1 is excited at 4 kHz with a carrier amplitude of 18.2 Vpp, supporting high-resolution angle detection over long motor leads. Sercos III communication is implemented through an RJ-45 8-pin port that adheres to the IEEE 802.3 physical layer, allowing deterministic Ethernet motion control. During power-up, the control unit draws a typical inrush of 6 A and thereafter maintains total consumption near 34 W, which eases cabinet thermal design. The RS-232 service lead can reach 15 m without signal repeaters, permitting remote console access on mezzanine or floor-level panels.

Analog Output Load
5 kΩ
Analog Output Resolution
19.5 mV/inc
Analog Output Voltage
5 V
Digital Output Per Channel
500 mA
Digital Output Per Group
1000 mA
En1 Excitation Freq
4 kHz
En1 Resolver Supply
18.2 Vpp
Max Pulse Width
60 ms
Probe Type 2 Pulse
4 μs
Probe Type 3 Pulse
200 μs
Rs232 Max Baud Rate
115 kBaud
Rs232 Max Cable Length
15 m
Sercos Iii Port
RJ-45, 8-pin
Sercos Iii Standard
IEEE 802.3
Typ Inrush Current
6 A
Typ Power Consumption
34 W
  • CDB011CS3ENSENSEN1EN1NNSNNFW
  • CDB01 1C S3 ENS ENS EN1 EN1 NN S NN FW
  • cdb01.1c-s3-ens-ens-en1-en1-nn-s-nn-fw
  • CDB1.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW:

Q: What is the analog output voltage of the CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW control unit?

A: The CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW offers an analog output voltage of 5 V, suitable for standard signal transmission applications.

Q: What is the typical inrush current for the CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW?

A: This control unit provides a typical inrush current of 6 A during startup.

Q: What analog output load can the CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW handle?

A: The analog output load supported by this model is 5 kΩ.

Q: What are the RS232 communication limits for the CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW?

A: The RS232 interface on this unit supports a maximum baud rate of 115 kBaud and cable lengths up to 15 meters.

Q: What is the maximum digital output current supported per channel and per group by this control unit?

A: Each digital output channel supports up to 500 mA, with a maximum of 1000 mA per group.


Internal Product Review

  • ‘‘The CDB01.1C-S3-ENS-ENS-EN1-EN1-NN-S-NN-FW is a Bosch Rexroth Indramat control unit with 34 W typical power consumption and 6 A typical inrush current. Sercos III communication through an RJ-45 8-pin port and IEEE 802.3 compliance give the platform straightforward network integration, making the control unit a very capable choice for motion systems.’’