The Bosch Rexroth Indramat CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW is part of the CDB Control Units series, supporting two axes and utilizing SERCOS III for control communication. This unit features 19.5 mV analog output resolution, a 9 watt base power consumption, and supports Safe Motion safety technology. It provides an RS232 serial interface, a maximum serial rate of 115 kBaud, and relay contacts rated at 24 volts DC and 1 amp.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW is a control unit from the CDB Control Units series produced by Bosch Rexroth Indramat. Intended for multi-axis drive assemblies, the module provides motion command processing and safety supervision within automated machinery. By integrating encoder supplies, fieldbus communication, and local I/O in one slot card, it acts as the interface between IndraDrive power sections and higher-level controllers on the plant floor. This arrangement lets one card manage position feedback, command exchange, and local signal handling from a central point in the drive assembly.
This card supports 2 drive axes and draws a base load of 9 W from the internal 24 V control bus when idle. Motion commands and parameter data move over SERCOS III, while maintenance and diagnostics can be handled through an RS232 service port. Each analog output steps in 19.5 mV increments, allowing fine process trimming. Two probe inputs capture position markers for registration tasks. The digital outputs can sink or source up to 500 mA, which is suitable for status lamps or similar control loads. Start-up strain on the supply is limited by an inrush draw of 6 A, and the combination of fieldbus communication and local service access supports normal operation without interrupting the control structure.
During energization the inrush window lasts only 60 ms, reducing stress on upstream power supplies. Continuous serial diagnostics reach 115 kBaud for trace capture and status monitoring. The form-C relay carries control logic out to external devices at DC 24 V, 1 A, isolating field wiring from the backplane. Functional safety is handled by the integrated Safe Motion package, enabling certified stop and speed limits without additional hardware. Encoder port 2 delivers 5.0 V at 350 mA for incremental transducers, while the ENS port supplies 11.6 V to multi-turn devices through a separate encoder supply path.
Frequently Asked Questions about CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW:
Q: What type of control communication does the CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW use?
A: The CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW supports control communication via SERCOS III.
Q: How many axes can the CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW control?
A: This control unit supports two axes for motion control tasks.
Q: What is the analog output resolution of the CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW?
A: Its analog output provides a resolution of 19.5 mV per increment.
Q: What is the maximum digital output current available on the CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW?
A: The digital outputs on this model can supply up to 500 mA of current.
Q: What safety technology is included with the CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW control unit?
A: The CDB01.1C-S3-ENS-EN2-EN2-S2-S-NN-FW features integrated Safe Motion safety technology.