4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911318870

No Tariffs On US Orders
  • Rated 4.6 (18 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW belongs to the CDB Control Units series and is equipped with a SERCOS III control communication interface. It features EnDat 2.1, 1 Vpp, and 5 V TTL encoder interfaces, as well as analog output ratings of 5 V and 1 mA. The unit supports relay contact voltages up to DC 24 V and digital output currents of 500 mA.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW is a motion-control card built by Bosch Rexroth Indramat for the CDB Control Units series. Installed in an IndraDrive housing, it supervises two servo axes and interfaces directly with higher-level automation over a fiber-optic ring. The board issues setpoints, monitors feedback, and processes safety signals, allowing coordinated positioning tasks without additional standalone controllers. Because it occupies a drive slot rather than a remote panel, wiring distances are shortened and electromagnetic noise on sensor lines is minimized.

The card communicates with upper-level devices through SERCOS III and forwards position data via an EnDat 2.1 / 1 Vpp / 5 V TTL encoder port. Two analog channels can source up to 1 mA or swing to 5 V for reference generation. Digital inputs register an ON state at 15 V, while the transistorized outputs can switch loads up to 500 mA. A probe circuit accepts edge-triggered signals, tolerates 3 mA of sink current at 24 V, and recognizes pulses as short as 4 µs for marker tracks or registration sensors in high-speed packaging equipment. All output stages include suppression to limit inductive kickback so that stored energy from solenoid coils is dissipated safely within the drive.

For heavier electromechanical devices, the relay channel absorbs up to 400 mJ per actuation, carries 1 A continuously, and is rated for DC 24 V circuits. Mechanical endurance reaches 1 × 108 operations, which supports long service intervals in indexing machinery. A front-panel D-sub port provides RS-232 diagnostics over cable runs to 15 m, providing direct access to parameter lists without disturbing the real-time network. The unit can drive contactors, read short probe pulses, and stream status data while the motion loop remains closed inside the drive chassis.

Analog Output Current
1 mA
Analog Output Voltage
5 V
Control Communication
SERCOS III
Digital Input On Level
15 V
Digital Output Current
500 mA
Encoder Interface
EnDat 2.1 / 1 Vpp / 5 V TTL
Inductive Load Energy
400 mJ
Probe Input Current
3 mA
Probe Input Voltage
24 V
Probe Pulse Width
4 µs
Relay Contact Current
1 A
Relay Contact Voltage
DC 24 V
Relay Mechanical Cycles
1 × 10^8
Rs232 Max Cable
15 m
  • CDB011CS3EN2EN2NNNNNNNNSNNFW
  • CDB01 1C S3 EN2 EN2 NNN NNN NN S NN FW
  • cdb01.1c-s3-en2-en2-nnn-nnn-nn-s-nn-fw
  • CDB1.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW:

Q: What is the maximum analog output current of the CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW control unit?

A: The CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW provides a maximum analog output current of 1 mA.

Q: Which control communication protocol is supported by the CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW?

A: This unit uses SERCOS III for its control communication interface.

Q: What types of encoder interfaces does the CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW support?

A: The supported encoder interfaces include EnDat 2.1, 1 Vpp, and 5 V TTL.

Q: What is the probe input voltage supported by the CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW control unit?

A: The maximum probe input voltage for this model is 24 V.

Q: What is the maximum cable length permitted for RS232 on the CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW?

A: The maximum cable length for RS232 connection on this unit is 15 meters.


Internal Product Review

  • ‘‘The CDB01.1C-S3-EN2-EN2-NNN-NNN-NN-S-NN-FW is an advanced CDB control unit from Bosch Rexroth Indramat, offering SERCOS III communication and a versatile encoder interface supporting EnDat 2.1, 1 Vpp, and 5 V TTL. With digital outputs rated at 500 mA and relay contacts capable of 1 A at 24 V DC, this unit is well-suited for demanding automation environments. The high cycle rating of the relay ensures reliable long-term performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo