4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911383961

No Tariffs On US Orders
  • Rated 4.5 (65 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 53 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW is part of the CDB Control Units series and features SERCOS III control communication. It provides two EnDat 2.1 encoder feedback channels and supports analog output at 5 V and 1 mA. The unit has galvanic isolation for emulation and a base power consumption of 9 W.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW is a drive control unit built by Bosch Rexroth Indramat for the CDB Control Units series. It serves as the control section of an IndraDrive axis, managing motion commands, processing encoder feedback, and generating communication signals to the associated power stage. Inside industrial automation equipment, the module ensures that servo motors follow position, speed, and torque references with the required accuracy.

Communication to higher-level motion controllers is handled over SERCOS III, giving deterministic cyclic data exchange for multi-axis coordination. The base electronics draw 9 W, so cabinet thermal load remains low during standby. For local reference generation, the unit provides an analog output rated at 5 V, 1 mA, suitable for driving external set-point inputs or test equipment. Encoder signal conversion circuits are galvanically isolated, which helps prevent ground loops between motor feedback devices and the control backplane. When EnDat feedback is used, the sense leads can be routed up to 75 m from the drive without signal boosters, and the module reproduces position data as 2 × EnDat 2.1 / 1 Vpp / 5 V TTL formats so legacy and modern evaluation channels receive identical information.

The relay output can switch up to 30 V DC and carry 1 A DC, letting machine logic actuate brakes or status indicators without an external contactor. Parameter download and service diagnostics use the Mini-DIN RS-232 connector, and the port supports a sustained data rate of 115 kBaud for parameter transfer and runtime traces. The dedicated EN2 section requires 6 W and supplies the feedback transducers with a regulated 5 V source. Internal option areas also include a MEM memory module that consumes 2 W and an S3 safety module that consumes 1 W, allowing accurate thermal planning for multi-axis racks.

Analog Output
5 V, 1 mA
Base Power Consumption
9 W
Control Communication
SERCOS III
Emulation Isolation
Galvanically Isolated
En2 Cable Length (sense)
75 m
En2 Module Power
6 W
Encoder Emulation
Absolute And Incremental
Encoder Feedback Type
2 x EnDat 2.1 / 1 Vpp / 5 V TTL
Encoder Supply Voltage
5 V
Mem Module Power
2 W
Relay Contact Current
1 A DC
Relay Contact Voltage
30 V DC
Rs232 Connector
Mini-DIN, 8-pin
Rs232 Data Rate
115 kBaud
S3 Module Power
1 W
  • CDB011CS3EN2EN2NNNMEMNNSNNFW
  • CDB01 1C S3 EN2 EN2 NNN MEM NN S NN FW
  • cdb01.1c-s3-en2-en2-nnn-mem-nn-s-nn-fw
  • CDB1.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW:

Q: What is the analog output specification on the CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW control unit?

A: The CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW offers analog output rated at 5 V and 1 mA for signal interfacing.

Q: What control communication protocol is supported by the CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW?

A: This model communicates via the SERCOS III protocol for control integration.

Q: Which encoder feedback types does the CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW accept?

A: Two feedback channels support EnDat 2.1, 1 Vpp, and 5 V TTL encoder signals.

Q: What are the relay contact ratings on the CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW?

A: The relay contacts are rated for 1 A DC and up to 30 V DC switching.

Q: How is emulation isolation achieved in the CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW?

A: Galvanic isolation is provided for emulation isolation on this unit.


Internal Product Review

  • ‘‘The CDB01.1C-S3-EN2-EN2-NNN-MEM-NN-S-NN-FW is a Bosch Rexroth Indramat CDB control unit with SERCOS III communication, well suited for precise drive integration. Dual encoder feedback for 2 x EnDat 2.1 / 1 Vpp / 5 V TTL and absolute-and-incremental encoder emulation support dependable signal handling in motion systems. Low 9 W base power consumption adds efficient operation to an already capable control platform.’’