4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW Bosch Rexroth Indramat

MPN: R911335644

No Tariffs On US Orders
  • Rated 4.6 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 17 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW is a control unit from the CDB Control Units series featuring SERCOS III communication with an RJ-45 8-pin connector. It includes two EN1 encoder interfaces that support resolver or HSF encoder types, and provides an 8 V encoder supply. The device offers two differential analog input channels and two analog output channels, both with ±10 V range and 12-bit resolution.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW control unit is manufactured by Bosch Rexroth Indramat within the CDB Control Units series. It is a plug-in controller module that supplies communication links, encoder handling, and analog I/O to drive inverters so that motion axes can be coordinated in industrial automation cells. By consolidating signal processing and network connectivity, the board reduces wiring complexity and enables deterministic command execution inside packaging lines, material handling equipment, and assembly machines.

The basic board draws 9 W during normal operation, so thermal loading inside the drive rack remains low. Command traffic is exchanged over SERCOS III, and the network port is an RJ-45, 8-pin connector that accepts standard industrial Ethernet patch leads. Two independent feedback ports identified as 2x EN1 accept signals from supported encoders, while resolver or HSF formats are also recognized. Typical inrush demand peaks at 6 A, and the surge lasts no more than 60 ms, which helps size upstream circuit protection. After stabilization, the module conditions encoder feedback and routes position words directly to the drive control core.

For feedback power, the control unit provides 8 V to the encoder terminals, while the resolver winding receives 18.2 Vpp at 4 kHz, allowing absolute rotor angle reconstruction. The MA1 option extends signal conditioning with two differential input channels rated at ±10 V and two voltage outputs over the same span. Both the inputs and outputs share 12 bits of resolution, giving 4096 discrete levels for closed-loop command values. This arrangement supports analog reference exchange and status signaling without requiring a separate interface board. These analog resources complement the digital communication functions, forming a single-card solution for drive control tasks without external breakout hardware.

Basic Board Power
9 W
Comm Connector
RJ-45, 8-pin
Control Communication
SERCOS III
Encoder Interfaces
2x EN1
Encoder Supply
8 V
Encoder Type
Resolver / HSF
Ma1 Analog Inputs
2 Differential Channels
Ma1 Analog Outputs
2 Channels
Ma1 Input Range
±10 V
Ma1 Input Resolution
12 bits
Ma1 Output Range
±10 V
Ma1 Output Resolution
12 bits
Max Inrush Pulse
60 ms
Resolver Excitation
18.2 Vpp
Resolver Frequency
4 kHz
Typ Inrush Current
6 A
  • CDB011CS3EN1EN1NNNMA1NNSNNFW
  • CDB01 1C S3 EN1 EN1 NNN MA1 NN S NN FW
  • cdb01.1c-s3-en1-en1-nnn-ma1-nn-s-nn-fw
  • CDB1.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW:

Q: What control communication protocol does the CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW support?

A: The control communication on the CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW uses the SERCOS III standard.

Q: How many analog input channels are available and what are their specifications?

A: This control unit is equipped with two differential analog input channels, each supporting a ±10 V range with 12-bit resolution.

Q: What type and quantity of encoder interfaces are available on this model?

A: There are two encoder interfaces provided, both supporting EN1 standard, for flexible feedback integration.

Q: What type of communication connector is included with this control unit?

A: The CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW features an RJ-45, 8-pin communication connector for data exchange.

Q: What are the max inrush pulse and typical inrush current specifications for this unit?

A: The maximum inrush pulse duration is 60 ms, with a typical inrush current of 6 A.


Internal Product Review

  • ‘‘The CDB01.1C-S3-EN1-EN1-NNN-MA1-NN-S-NN-FW is a Bosch Rexroth Indramat control unit with SERCOS III communication and dual EN1 encoder interfaces. The MA1 analog section adds 2 differential input channels with a ±10 V range, supporting precise signal handling in motion applications. This unit stands out as a well-configured control platform for demanding servo systems.’’