CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW Bosch Rexroth Indramat
MPN: R911341009
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
13 Seconds
The Bosch Rexroth Indramat CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW is part of the CDB Control Units series and features a double-axis configuration with Multi-Ethernet communication and RS232 serial interface. This control unit offers an analog input range of ±10 V, a control supply of DC 24 V, and a power consumption of 9 watts. It includes RJ-45 8-pin Ethernet ports, combined I/O rated at 24 V / 0.5 A, and a relay contact rating of 24 V / 1 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat produced the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW, a plug-in control card in the CDB Control Units series for IndraDrive modular drives. The board serves as the central processing layer between motion controllers and power inverters by handling axis regulation, fieldbus communication, and local I/O tasks. In an automation cabinet, it supports motion sequencing, parameter storage, and diagnostic access for servo or spindle drives used in packaging, handling, and machine-tool applications. Its plug-in format keeps the control functions separate from the power stage while allowing both sections to operate as one coordinated drive system.
The board accepts differential command signals over an analog input range of ±10 V, and its input resistance of 160 kΩ keeps the upstream source lightly loaded while helping reject electrical noise. For reference generation or monitoring, an isolated analog output is rated at 5 V / 1 mA. Motion and diagnostic data are exchanged through a Multi-Ethernet interface that supports the 100Base-TX physical layer, so standard CAT5e cabling can be used for runs up to 100 m. An RS232 service port is also available for local access, while the control electronics draw logic power from an external 24 V DC supply and protective circuitry limits transient input pulse width to 60 ms.
An internal terminal block helps route wiring for both axes and shared peripherals inside the drive assembly. The unit can regulate two servo drives at the same time through its Double-Axis configuration, and discrete sensors or solenoids can be supplied by the combined I/O rail rated at 24 V / 0.5 A. During startup, inrush current peaks at 6 A, after which normal operation requires only 9 W of power. Additional connections include a 24 V / 3 mA probe input for touch-trigger sensing and a 24 V / 1 A relay contact for brake release, and any required safety functions must be provided by external hardware.
Frequently Asked Questions about CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW:
Q: What is the analog input voltage range for the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW control unit?
A: The CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW supports analog input signals in the range of ±10 V.
Q: How many axes can the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW control at once?
A: This unit is designed for double-axis configuration, managing two independent axes simultaneously.
Q: What type of communication does the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW use for control integration?
A: The control communication uses Multi-Ethernet, allowing for flexible network connectivity.
Q: What is the combined input/output voltage and current rating of the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW?
A: The maximum combined I/O rating for this unit is 24 V at 0.5 A.
Q: Which Ethernet interface is supported by the CDB01.1C-ET-NNN-NNN-NNN-NNN-NN-S-NN-FW for network connections?
A: It supports an Ethernet connection using a 100Base-TX port with an RJ-45, 8-pin connector.