CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW Bosch Rexroth Indramat
MPN: R911327027
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
50 Seconds
The Bosch Rexroth Indramat CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW is part of the CDB Control Units series and features a Multi-Ethernet command interface with support for two network ports. This unit includes seven digital inputs at 24 V, two analog outputs with 8-bit DAC and 5 V output, and has a relay contact rating of 1 ampere. It supports a serial cable length of up to 15 meters and can handle a maximum I/O supply current of 1.1 A.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW is a modular control section produced by Bosch Rexroth Indramat within the CDB Control Units series. Intended for IndraDrive power inverters, the unit supplies centralized processing and field-level I/O so axes can be coordinated, monitored, and adjusted in industrial automation lines. It plugs onto a power section and provides the real-time link between higher-level PLC networks and the drive’s internal torque or position loops. The design concentrates signal conditioning, communication, and safety relay functions on one card to reduce cabinet wiring.
Two analog outputs use an 8 bit digital-to-analog converter that steps voltage changes in increments of 19.5 mV/inc. Each channel can swing from 0 to 5 V to command torque or speed references. The seven digital inputs accept sourcing signals at 24 V while drawing only 3 mA per point, allowing direct wiring to typical sensor blocks. Digital outputs are rated for sink currents up to 500 mA, so external contactors or indicator lamps can be driven without intermediate relays. A Multi-Ethernet command interface and two network ports let the drive join Profinet, EtherNet/IP, or SERCOS III segments without add-on cards. For parameter loading and service, the RS-232/RS-485 port transfers data at up to 115 kBaud over cables as long as 15 m. All I/O circuits share a common supply that must not exceed 1.1 A.
Each analog channel sources up to 1 mA, which is enough to drive standard control card inputs while minimizing load on the converter. Fast edge capture is available through the probe input, which recognizes position marker signals with a pulse width as short as 4 µs. For auxiliary switching, an onboard relay carries up to 1 A, which is useful for enabling brakes or safety interlocks directly from the unit. These limits apply to connected control circuits, position marker detection, and auxiliary switching functions in multi-axis machinery.
Frequently Asked Questions about CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW:
Q: How many digital inputs are available on the CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW and what are their electrical characteristics?
A: The CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW control unit features 7 digital inputs, each operating at 24 V with a current rating of 3 mA.
Q: What are the specifications for analog outputs on the CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW control unit?
A: This unit provides two analog outputs with a resolution of 19.5 mV per increment and an 8-bit DAC.
Q: What is the maximum I/O supply current supported by the CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW?
A: A maximum of 1.1 A can be supplied to connected input/output devices via this control unit.
Q: How many network ports does the CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW have and what type of network interface does it utilize?
A: The CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW offers two network ports and supports a Multi-Ethernet command interface.
Q: What are the maximum serial cable length and baud rate for the CDB01.1C-ET-NNN-NNN-NNN-NNN-L1-S-NN-FW?
A: The maximum serial communication cable length for this control unit is 15 meters, with a top baud rate of 115 kBaud.