The Bosch Rexroth Indramat CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW is part of the CDB Control Units series and features MultiEthernet communication. This control unit offers analog input ranges of ±10 V with a 160 kΩ impedance, digital input voltage of 24 V at 3 mA, and a control power consumption of 23.2 W. Its encoder interfaces support IndraDyn, HIPERFACE, 1 Vpp, and TTL signals.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW belongs to the CDB Control Units series produced by Bosch Rexroth Indramat. Mounted on an IndraDrive system, this control unit coordinates input, output, and feedback channels so that connected servo or spindle drives follow motion commands issued by a supervisory PLC. It supports Multi-Ethernet transport layers and supplies the signal conditioning required for analog process values and 24 VDC machine wiring. The device is installed where compact drive-level intelligence is preferred over separate remote I/O modules.

The analog front end presents an input impedance of 160 kΩ; this high value minimizes loading on external transducers tied to the ±10 V differential range accepted by each channel. Outgoing reference loops are available as sourcing drivers that can supply 1 mA at up to 5 V, enabling speed or torque setpoints to be delivered directly to legacy drives. For networked applications, the integrated MultiEthernet interface handles real-time messaging without an additional communication card. Digital control lines draw only 3 mA per input at 24 V, while transistor outputs can switch 0.5 A for solenoids or contactors. During power-up the module withstands an inrush of 6 A for 60 ms, after which steady-state electronics operate from the internal 24 V bus.

Total control electronics consumption is rated at 23.2 W, a figure useful when sizing the auxiliary supply rail for multi-axis systems. The enclosure measures 103 mm deep, 49.5 mm wide, and 322.6 mm high, allowing several units to be stacked densely on a drive stack without exceeding typical cabinet depths. Across all 16 digital inputs, the current demand remains modest, which helps ease power budgeting. The high-side outputs can actuate relays or small pneumatic valves directly without an intermediate interface relay.

Analog Input Impedance
160 kΩ
Analog Input Range
±10 V
Analog Output Current
1 mA
Analog Output Voltage
5 V
Communication
MultiEthernet
Control Power
23.2 W
Depth
103 mm
Digital Input Current
3 mA
Digital Input Voltage
24 V
Digital Output Current
0.5 A
Encoder Interface 1
IndraDyn / HIPERFACE / 1 Vpp / TTL
Encoder Interface 2
IndraDyn / HIPERFACE / 1 Vpp / TTL
Height
322.6 mm
Inrush Current
6 A
Inrush Pulse Width
60 ms
Width
49.5 mm
  • CDB011CETENSENSNNNNNNNNSNNFW
  • CDB01 1C ET ENS ENS NNN NNN NN S NN FW
  • cdb01.1c-et-ens-ens-nnn-nnn-nn-s-nn-fw
  • CDB1.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW

Frequently Asked Questions about CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW:

Q: What type of communication interface does the CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW control unit use?

A: The CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW supports MultiEthernet communication for flexible network integration.

Q: Which encoder interfaces are available on the CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW?

A: This unit is capable of supporting two encoder interfaces: IndraDyn, HIPERFACE, 1 Vpp, and TTL.

Q: How much control power does the CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW require?

A: The control power consumption for this model is 23.2 watts.

Q: What is the analog input range and impedance on the CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW?

A: The analog input range for this device is ±10 volts with an input impedance of 160 kΩ.

Q: What is the digital output current capability of the CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW?

A: The maximum digital output current on this unit is 0.5 A at 24 V digital input voltage.


Internal Product Review

  • ‘‘The CDB01.1C-ET-ENS-ENS-NNN-NNN-NN-S-NN-FW is a Bosch Rexroth Indramat CDB control unit that stands out for MultiEthernet communication and dual IndraDyn/HIPERFACE/1 Vpp/TTL encoder interfaces. Analog handling is well suited for precise control, combining a ±10 V input range with 160 kΩ input impedance. A strong choice for integrated automation platforms where stable feedback processing and clean network connectivity are priorities.’’