The Bosch Rexroth Indramat CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW is a control unit from the CDB Control Units series with support for two axes. It features fieldbus connectivity including SERCOS III, EtherCAT, and PROFINET, as well as an Ethernet RJ-45 connector supporting 100Base-TX. The unit also provides two MA1 channels with 12-bit resolution and several safety-rated connections such as a D-Sub 9-pin female safety connector and relay rated at 24 VDC, 1 A.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW is a modular control unit from Bosch Rexroth Indramat that belongs to the CDB Control Units series. Designed for multi-axis drive applications, the module coordinates motion commands, manages safety signals, and links drives to higher-level automation networks. By combining local analog and digital I/O with fieldbus and Ethernet connectivity, the unit acts as the control layer inside IndraDrive servo systems. This arrangement lets one module supervise axis behavior, exchange status data with connected devices, and keep cabinet layouts compact.

The unit coordinates motion on 2 axes and maintains deterministic response with a base draw of 9 W from the 24 V control supply. Its RJ-45, 8-pin port complies with the 100Base-TX standard, allowing fast data exchange across Ethernet-based automation networks. When the cabinet is first energized, the electronics demand an inrush of 6 A, which helps set protection for the control circuit. The MA1 option adds two inputs and two outputs with 12-bit resolution, and each channel operates across a ±10 V signal range. A dedicated RS-232 serial interface is available for diagnostics and local service access.

The safety block connects through a D-Sub, 9-pin female plug and is integrated directly into the controller. Each safe input operates at 24 VDC, 3 mA, while the solid-state outputs are rated for 24 VDC, 0.5 A to drive contactors or indicator lamps. An auxiliary relay can switch loads up to 24 VDC, 1 A for redundant shutdown chains, and the permissible pulse width on safety signals is limited to 60 ms. The ENS encoder interface draws only 6 W, which helps keep internal heat generation low when feedback modules are installed. Separate safety, encoder, and communication connections help organize wiring in dense drive cabinets.

Axes
2
Base Power Consumption
9 W
Ens Power Consumption
6 W
Ethernet Connector
RJ-45, 8-Pin
Ethernet Standard
100Base-TX
Fieldbus Support
SERCOS III, EtherCAT, PROFINET
Inrush Current
6 A
Ma1 Channels
2 In / 2 Out
Ma1 Resolution
12 Bits
Ma1 Signal Range
±10 V
Max Pulse Width
60 ms
Safety Connector
D-Sub, 9-Pin Female
Safety Input Level
24 VDC, 3 mA
Safety Output Rating
24 VDC, 0.5 A
Safety Relay Rating
24 VDC, 1 A
Serial Interface
RS232
  • CDB011CETENSENSNNNMA1S2SNNFW
  • CDB01 1C ET ENS ENS NNN MA1 S2 S NN FW
  • cdb01.1c-et-ens-ens-nnn-ma1-s2-s-nn-fw
  • CDB1.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW

Frequently Asked Questions about CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW:

Q: How many axes can the CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW manage?

A: This control unit supports up to 2 axes, allowing multi-axis machine control.

Q: What type of Ethernet connector is used on this control unit?

A: The CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW features an RJ-45, 8-pin connector for Ethernet communication.

Q: Which fieldbus protocols does the CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW support?

A: Supported fieldbus protocols on this model include SERCOS III, EtherCAT, and PROFINET for flexible integration.

Q: What is the MA1 channel signal range and resolution on this control unit?

A: The MA1 channels have a resolution of 12 bits and accommodate a ±10 V signal range.

Q: What safety input level does the CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW require?

A: The safety input level for this unit is 24 VDC at 3 mA, ensuring safe monitoring and operation.


Internal Product Review

  • ‘‘The CDB01.1C-ET-ENS-ENS-NNN-MA1-S2-S-NN-FW is a Bosch Rexroth Indramat CDB control unit with 2-axis capability and 100Base-TX Ethernet connectivity. An RJ-45 8-pin Ethernet connector and support for SERCOS III, EtherCAT, and PROFINET make network integration especially flexible for modern motion platforms. The 2 In / 2 Out MA1 interface with a ±10 V signal range adds practical analog versatility, making this unit a strong choice for precise multi-axis control.’’